Preanalytical Nonconformity Management Regarding Primary Tube Mixing in Brazil

Author:

Lima-Oliveira Gabriel,Guidi Gian Cesare,Guimaraes Andre Valpassos Pacifici,Correa Jose Abol,Lippi Giuseppe

Abstract

Summary Background: The multifaceted clinical laboratory process is divided in three essential phases: the preanalytical, analytical and postanalytical phase. Problems emerging from the preanalytical phase are responsible for more than 60% of laboratory errors. This report is aimed at highlighting and discussing nonconformity (e.g., nonstandardized procedures) in primary blood tube mixing immediately after blood collection by venipuncture with evacuated tube systems. Methods: From January 2015 to December 2015, fifty different laboratory quality managers from Brazil were contacted to request their internal audit reports on nonconformity regarding primary blood tube mixing immediately after blood collection by venipuncture performed using evacuated tube systems. Results and Conclusions: A minority of internal audits (i.e., 4%) concluded that evacuated blood tubes were not accurately mixed after collection, whereas more than half of them reported that evacuated blood tubes were vigorously mixed immediately after collection, thus magnifying the risk of producing spurious hemolysis. Despite the vast majority of centers declaring that evacuated blood tubes were mixed gently and carefully, the overall number of inversions was found to be different from that recommended by the manufacturer. Since the turbulence generated by the standard vacuum pressure inside the primary evacuated tubes seems to be sufficient for providing solubilization, mixing and stabilization between additives and blood during venipuncture, avoidance of primary tube mixing probably does not introduce a major bias in tests results and may not be considered a nonconformity during audits for accreditation.

Publisher

Centre for Evaluation in Education and Science (CEON/CEES)

Reference14 articles.

1. for Standardization Medical laboratories Requirements for quality and competence ISO document for Standardization;Geneva;International Organization International Organization,2012

2. Inversion of lithium heparin gel tubes after centrifugation is a significant source of bias in clinical chemistry testing;Lippi;Clin Chim Acta,2014

3. Laboratory diagnostics and quality of blood collection;Lima;J Med Biochem,2015

4. Pre - test and post - test applications to shape the education of phlebotomists in a quality management program : An experience in a training hospital;Aykal;J Med Biochem,2016

5. Processing of diagnostic blood specimens : Is it really necessary to mix primary blood tubes after collection with evacuated tube system;Lima;Biopreserv Biobank,2014