Comparative biomechanical evaluation of two technologically different microprocessor-controlled prosthetic knee joints in safety-relevant daily-life situations

Author:

Bellmann Malte,Köhler Thomas Maximilian,Schmalz Thomas

Abstract

Abstract Safety-relevant gait situations (walking on stairs and slopes, walking backwards, walking with small steps, simulated perturbations of swing phase extension) were investigated in a motion analysis laboratory with six unilateral transfemoral amputees using two different microprocessor-controlled prosthetic knee joints (Rheo Knee XC, C-Leg). A randomized crossover design was chosen. The study results imply that the performance and safety potential of a microprocessor-controlled knee joint can be associated with the individual control algorithms and the technological concepts that are implemented to generate motion resistances for controlling flexion and extension movements. When walking with small steps, advantages of the “default swing” concept used in the Rheo Knee XC were identified due to a highly reproducible swing phase release. However, when walking backwards, this concept may lead to an uncontrolled knee flexion which partly resulted in falls. When walking down stairs, walking on slopes or while recovering from a stumble after perturbations of the swing phase extension, the C-Leg demonstrated a reliable prosthetic side load-bearing capacity resulting in reduced loading on the residual body. In contrast, the Rheo Knee XC required increased compensatory movements of the remaining locomotor system in order to compensate for reduced load-bearing and safety reserves.

Publisher

Walter de Gruyter GmbH

Subject

Biomedical Engineering

Reference56 articles.

1. Impact of stance phase microprocessor-controlled knee prosthesis on ramp negotiation and community walking function in K2 level transfemoral amputees;Prosthet Orthot Int,2012

2. Functional principles of current microprocessor-controlled prosthetic knee joints;Orthopädie-Technik,2009

3. Energy expenditure and biomechanical characteristics of lower limb amputee gait: the influence of prosthetic alignment and different prosthetic components;Gait Posture,2002

4. Foot trajectory in human gait: a precise and multifactorial motor control task;Phys Ther,1992

5. Comparative biomechanical analysis of current microprocessor-controlled prosthetic knee joints;Arch Phys Med Rehabil,2010

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献