Factors associated with extubation failure in very low birth weight infants: a cohort study in the northeast Brazil
Author:
Teixeira Raphaela Farias123ORCID, Costa Cinthia Maria3, Maria de Abreu Catarina2, Lessa Cicero Amsterdan2, Carvalho Aline Carla2, Kassar Samir Buainain2, Barreto Ikaro Daniel4, Gurgel Ricardo Queiroz1, Medeiros Andrea Monteiro1
Affiliation:
1. Graduate Program in Health Sciences , Federal University of Sergipe , Aracaju , Sergipe , Brazil 2. CESMAC University Centre , Maceió , Alagoas , Brazil 3. Santa Monica Maternity School Hospital , Maceió , Alagoas , Brazil 4. Federal Rural University of Pernambuco , Recife , Brazil
Abstract
Abstract
Objectives
Identifying and understanding the main risk factors associated with extubation failure of very low birthweight (VLBW) infants in different populations can subsequently help in establishing better criteria while taking decision of extubation. The aim of the study was to identify factors associated with extubation failure in VLBW infants.
Methods
A cohort study of VLBW infants who underwent their first extubation between April 2018 and December 2019 in a Neonatal Intensive Care Unit, Alagoas, Brazil, were included in this study. Extubation failure was defined as reintubation within seven days of extubation. Relative risks of predictive variables different between the extubation success group (ES) and extubation failure group (EF) were estimated with a robust Poisson regression model.
Results
Out of the 112 infants included, 26 (23%) cases exhibited extubation failure. Extremely low birth weight (RR 2.55, 95% CI 1.07, 6.06), mechanical ventilation duration for first extubation greater than seven days (RR 2.66, 95% CI 1.10, 6.45), vaginal delivery (RR 2.07, 95% CI 1.03, 4.18) and maternal chorioamnionitis (RR 4.89, 95% CI 1.26–18.98) remained independently associated with extubation failure. EF had a significant greater need for respiratory support, longer oxygen therapy duration, more bronchopulmonary dysplasia (BPD) and longer length of hospital stay, even when adjusted for confounding variables.
Conclusions
Extremely low birth weight infants needing mechanical ventilation, wherein the duration for first extubation was longer than seven days, with vaginal delivery and maternal chorioamnionitis failed more frequently at the first attempt of extubation. And this failure increased the risk of BPD and the length of hospital stay.
Funder
Scientific Initiation Seed Program at Cesmac University Center – SANTANDER
Publisher
Walter de Gruyter GmbH
Subject
Obstetrics and Gynaecology,Pediatrics, Perinatology, and Child Health
Reference40 articles.
1. Blencowe, H, Krasevec, J, de Onis, M, Blencowe, H, Krasevec, J, de Onis, M, et al.. National, regional, and worldwide estimates of low birth weight in 2015, with trends from 2000: a systematic analysis. Lancet Glob Health 2019;7:e849–60. https://doi.org/10.1016/s2214-109x(18)30565-5. 2. Fanaroff, AA, Stoll, BJ, Wright, LL, Avroy, A, Carlo, WA, Ehrenkranz, RA, et al.. Trends in neonatal morbidity and mortality for very low birth weight infants. Am J Obstet Gynecol 2007;196:147.e1–8. https://doi.org/10.1016/j.ajog.2006.09.014. 3. Eichenwald, EC, Stark, AR. Management and outcomes of very low birth weight. N Engl J Med 2008;358:1700–11. https://doi.org/10.1056/nejmra0707601. 4. Chawla, S, Natarajan, G, Shankaran, S, Carper, B, Brion, LP, Keszler, M, et al.. Markers of successful extubation in extremely preterm infants, and morbidity after failed extubation. J Pediatr 2017;189:113–19.e2. 5. Walsh, MC, Morris, BH, Wrage, LA, Vohr, BR, Poole, WK, Tyson, JE, et al.. Extremely low birth weight neonates with protracted ventilation: mortality and 18-month neurodevelopment outcomes. J Pediatr 2005;146:798–804. https://doi.org/10.1016/j.jpeds.2005.01.047.
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|