The effectiveness of disinfection protocols in medical school osteopathic manipulative medicine labs

Author:

Patrizio Harrison A.1,Phyu Riley1,Boyle Thomas2,Schachter Todd3

Affiliation:

1. Rowan University School of Osteopathic Medicine , Stratford , NJ , USA

2. Department of Employee Health , Rowan University School of Osteopathic Medicine , Stratford , NJ , USA

3. Department of Family Medicine , Rowan University School of Osteopathic Medicine , Stratford , NJ , USA

Abstract

Abstract Context In light of the COVID-19 pandemic, healthcare-associated infections have taken center stage. Healthcare has adjusted workflows to accommodate for more robust disinfecting regiments to help protect the community. This has resulted in the need for medical institutions to reevaluate the current disinfection protocols down to the student level. The osteopathic manipulative medicine (OMM) laboratory provides an optimal avenue for assessing the effectiveness of medical students’ ability to clean examination tables. With OMM laboratories having a high level of interaction, adequate disinfection is important for the health and safety of students and teaching faculties. Objectives This study will evaluate the effectiveness of the current disinfection protocols in the medical school OMM labs. Methods A cross-sectional, nonrandomized study was performed on 20 OMM examination tables utilized for osteopathic training. Tables were chosen based on their close proximity to the podium. Close proximity was utilized as a criteria to increase the probability of utilization by students. The sampled tables were observed to ensure their use by students during class. Initial samples were collected in the morning after disinfection by Environmental Services. Terminal samples were collected after Osteopathic medical students utilized and disinfected the OMM examination tables. Samples were collected from the face-cradle and midtorso regions and analyzed utilizing adenosine triphosphate (ATP) bioluminescence assays with an AccuPoint Advanced HC Reader. This reader provides a digital readout of the quantity of light measured in relative light units (RLUs), which is directly correlated to the amount of ATP present in the sample, providing an estimated pathogen count. For statistical analysis, a Wilcoxon signed-rank test was utilized to find statistical differences in RLUs in samples after initial and terminal disinfection. Results The face cradle showed a 40 % increase in failure rate in samples after terminal disinfection when samples were compared after initial disinfection. A Wilcoxon signed-rank test revealed an estimated pathogen level for face cradle that was significantly higher after terminal disinfection (median, 4,295 RLUs; range, 2,269–12919 RLUs; n=20) compared to initial disinfection (median, 769 RLUs; range, 29–2,422 RLUs; n=20), z=−3.8, p=0.00008, with a large effect size, d=2.2. The midtorso region showed a 75 % increase in samples after terminal disinfection when samples were compared after initial disinfection. A Wilcoxon signed-rank test revealed that the estimated pathogen levels for midtorso were significantly higher after terminal disinfecting (median, 656 RLUs; range, 112–1,922 RLUs; n=20) compared to initial disinfecting (median, 128 RLUs; range, 1–335 RLUs; n=20), z=−3.9, p=0.00012, with a large effect size, d=1.8. Conclusions This study suggests that medical students frequently failed to disinfect high-touch regions on examination tables, such as the midtorso and the face cradle. It is recommended that the current OMM lab disinfection protocol be modified to include the disinfection of high-touch regions in order to reduce the possibility of pathogen transmission. Further research should explore the effectiveness of disinfection protocols in clinical settings such as outpatient offices.

Publisher

Walter de Gruyter GmbH

Subject

Complementary and alternative medicine,Complementary and Manual Therapy

Reference19 articles.

1. Magill, SS, Edwards, JR, Bamberg, W, Beldavs, ZG, Dumyati, G, Kainer, MA, et al.. Emerging infections program healthcare-associated infections and antimicrobial use prevalence survey team. Multistate point-prevalence survey of health care-associated infections. N Engl J Med. 2014;370:1198–208. https://doi.org/10.1056/NEJMoa1306801. Erratum in: N Engl J Med. 2022;386:2348. PMID: 24670166; PMCID: PMC4648343.

2. Cassini, A, Plachouras, D, Eckmanns, T, Abu Sin, M, Blank, HP, Ducomble, T, et al.. Burden of six Healthcare associated infections on European population health: estimating incidence-based disability-adjusted life years through a population prevalence-based modelling study. PLoS Med 2016;13:e1002150. https://doi.org/10.1371/journal.pmed.1002150.

3. Klevens, RM, Edwards, JR, Richards, CL, Horan, TC, Gaynes, RP, Pollock, DA, et al.. Estimating health associated infections and deaths in U.S. hospitals, 2002. Publ Health Rep 2007;122:160–6. https://doi.org/10.1177/003335490712200205.

4. Choi, H, Chatterjee, P, Lichtfouse, E, Martel, JA, Hwang, M, Jinadatha, C, et al.. Classical and alternative disinfection strategies to control the COVID-19 virus in healthcare facilities: a review. Environ Chem Lett 2021;19:1945–51. https://doi.org/10.1007/s10311-021-01180-4.

5. Lima de Miranda, K, Detlefsen, L, Stolpe, M. Overconfidence and hygiene non-compliance in hospitals, EconStor: overconfidence and hygiene non-compliance in hospitals kiel: kiel institute for the world economy (IfW); 1970. http://hdl.handle.net/10419/222296 [Accessed 26 Oct 2022].