Affiliation:
1. Institute of Thermal and Process Engineering, Faculty of Mechanical Engineering, Cracow University of Technology , Kraków , Poland
Abstract
Abstract
After a year of the heat exchanger operation in overload conditions, a number of cracks on the tube connections to the tubesheet have been observed. To explain the stress concentration and crack initiation, a finite element analysis is performed. A three-dimensional model is constructed and analyzed. To calculate more precisely the state of stress in the most loaded regions, a submodel is created. The maximum stress exceeds the allowable stress, and according to the standards, it can lead to ratcheting. To reduce stress concentration, all tubes should be shortened and corrugated tubes are installed in the high-temperature region from the side of the burner. A finite element model of the modified heat exchanger and a submodel are created. In the modified heat exchanger, ratcheting should not occur according to the applied standards. During the operation of the modified heat exchanger, there are no further problems with cracking.
Subject
Electrical and Electronic Engineering,Mechanical Engineering,Aerospace Engineering,General Materials Science,Civil and Structural Engineering,Environmental Engineering
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献