The paper presents the results of numerical computations performed for the furnace chamber waterwalls of a supercritical boiler with a steam output of 2400 × 103 kg/h. A model of distributed parameters is proposed for the waterwall operation simulation. It is based on the solution of equations describing the mass, momentum and energy conservation laws. The aim of the calculations was to determine the distribution of enthalpy, mass flow and fluid pressure in tubes. The balance equations can be brought to a form where on the left-hand side space derivatives, and on the right-hand side – time derivatives are obtained. The time derivatives on the right-hand side were replaced with backward difference quotients. This system of ordinary differential equations was solved using the Runge-Kutta method. The calculation also takes account of the variable thermal load of the chamber along its height. This thermal load distribution is known from the calculations of the heat exchange in the combustion chamber. The calculations were carried out with the zone method.
Reference13 articles.
1. Modelling thermal and flow phenomena occurring in the evaporator of a boiler with natural circulation Publishing House of Cracow University of Technology in Polish );Grądziel;Mechanika,2012
2. Mathematical modelling of tube heat exchangers with complex flow arrangement;Taler;Chem Process Eng,2011
3. Thermal Calculations of Steam Boilers Standard Method in Russian );Kuznetsov;Energy,1973
4. Dynamic simulation of large boilers with natural recirculation;Adam;Comp Chem Eng,1999
5. Thermal hydraulic analysis of a steam boiler with rifled evaporating tubes;Tucakovic;Appl Therm Eng,2007
Cited by
17 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献