Baadenhuijsen Henk,Kuypers Aldy,Weykamp Cas,Cobbaert Christa,Jansen Rob
Abstract
AbstractThe performance of suitable secondary reference material for the use of trueness control of six routinely measured clinical enzymes in the Dutch External Quality Assessment (EQA) scheme is described. The reference material of choice was selected using the split-patient-sample between-field method (twin study) design as described in an earlier study of the Calibration 2000 project in The Netherlands. This material, which was proven to be commutable for all wet chemistry systems, was implemented as the national enzyme calibrator. It consisted of a cryo-protected lyophilised serum with additions of recombinant human enzymes. Various batches of the frozen version of this material without cryo-protection additive, called native EQA samples, were used in the general EQA scheme for performance evaluation. The results of Calibration 2000 calibrated and non-Calibration 2000 calibrated laboratories were compared for both the regular (spiked with non-human enzymes) and native EQA samples in terms of precision and bias with established reference method values for the native samples. The regular samples showed mean between-laboratory CV ranges for all six enzymes involved (low–high) of 5.5–10.3% for the non-calibrated users vs. 4.6–10.8% for the calibrated users. For the native samples these respective ranges were 5.2–9.9% vs. 2.2–4.9%. Without exception, the group of Calibration 2000 calibrated users showed the lowest bias against the reference method values. Regular EQA samples (spiked with non-human enzymes) showed poorer performance than native samples and are not suitable for accuracy assessment purposes, the main aim of EQA schemes. Native samples that are commutable should be used for trueness control in current EQA schemes.
Subject
Biochemistry (medical),Clinical Biochemistry,General Medicine
Reference19 articles.
1. Multicenter evaluation of the commutability of a potential reference material for harmonization of enzyme activities;Scharnhorst;Clin Chem Lab Med,2004
2. Commutability assessment of potential reference material using a split - patient - sample between - field methods ( twin - study ) design : study within the framework of the Dutch project Calibration;Baadenhuijsen;Clin Chem,2000
3. Impact of reference materials on accuracy in clinical chemistry;Franzini;Clin Biochem,1998
4. Usefulness of reference materials in calibration of enzyme activities;Lessinger;Eur J Clin Chem Clin Biochem,1995
5. Trueness verification in European external quality assessment schemes : time to care about the quality of samples;Thienpont;Scand Clin Lab Invest,2003