Evaluation of immunoassays for the measurement of insulin-like growth factor-I and procollagen type III peptide, indirect biomarkers of recombinant human growth hormone misuse in sport

Author:

Abellan Rosario,Ventura Rosa,Pichini Simona,Pascual Jose A.,Pacifici Roberta,Di Carlo Simonetta,Bacosi Antonella,Segura Jordi,Zuccaro Piergiorgio

Abstract

AbstractInsulin-like growth factor-I (IGF-I) and procollagen type III peptide (P-III-P) have been proposed as indirect biomarkers for the detection of the misuse of recombinant human growth hormone in sport. An extended intra- and inter-laboratory validation of commercially available immunoassays was carried out. For total IGF-I, two radioimmunoassay (RIA) kits (IGF-I/RIA1, Nichols Institute Diagnostics and IGF-I/RIA2, Mediagnost) and one enzyme-linked immunosorbent assay (ELISA) (R&D) were evaluated. For P-III-P, two RIA kits (P-III-P/RIA3, Cis-bioInternational and P-III-P/RIA4, Orion Diagnostica) were studied. The intra-laboratory precision and accuracy values for all IGF-I assays were better than 15%. The IGF-I/ELISA showed the lowest limit of quantification (LOQ) and its calibration curve covered the range of concentrations found in human serum samples. Higher agreement between laboratory results was obtained for IGF-I/ELISA and IGF-I/RIA1. Low inter-technique correlation was obtained for the three assays; the only comparable results were obtained between IGF-I/ELISA and IGF-I/RIA1. For P-III-P, intra-laboratory precision and accuracy values better than 15% were obtained for both assays in almost all cases. The calibration curve for P-III-P/RIA4 covered the range of concentrations of serum samples, while 30% of the values for P-III-P/RIA3 were below the calibration sample with the lowest concentration. Inter-laboratory correlation was also higher for P-III-P/RIA4. In summary, ELISA and RIA4 were the most suitable assays for measurement of IGF-I and P-III-P, respectively, in serum samples. However, the validation studies carried out show the need for harmonization of immunoassay parameters to improve the reproducibility and comparability of results between different laboratories and in different studies.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry, medical,Clinical Biochemistry,General Medicine

Reference24 articles.

1. A new biomedical method procedure for testing the equality of measurements from two different analytical methods;Passing;J Clin Chem Clin Biochem,1983

2. Rapid equilibrium radioimmunoassay for the amino - terminal propeptide of human type III procollagen;Risteli;Clin Chem,1988

3. Radioimmunoassay for insulin - like growth factor - I : solutions to some potential problems and pitfalls;Breier;J Endocrinol,1991

4. Serum IGF - I is higher in gymnasts than runners and predicts bone and lean mass;Snow;Med Sci Sports Exerc,2000

5. Low - volume circuit versus high - volume periodized resistance training in women;Marx;Med Sci Sports Exerc,2001

Cited by 30 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3