AbstractPurpose: The aim of our study was to measure the inter-assay variation and accuracy of serum creatinine assays and to assess the effect of standardized calibration procedures on this variability. Methods: We analyzed 30 human sera and three reference materials, using 17 creatinine assays (12 colorimetric, 4 enzymatic and 1 HPLC). We compared two standardized calibration procedures, using either a reference material or secondary standards, to that recommended by the manufacturers. Results: For assays calibrated according to the manufacturers' recommendations, the median inter-assay coefficient of variation (CV) was 14.2% for 20 low samples (45–150μM), and 7.7% for 10 high samples (250–350μM). The CV was significantly influenced by the calibration procedure, but none of the standardized calibration procedures significantly improved the inter-assay variability. However, a significant decrease in CV was noted within each type of assay method (colorimetric or enzymatic) when the standardized calibration used standards of level(s) close to the concentrations to be measured. Only the compensated Jaffe technique and the amido-hydrolase assay showed bias of less than 10%. Conclusions: Standardizing calibration procedures is unlikely to decrease the analytical variability of creatinine assays enough to allow uniform and reliable use of the equations for estimation of glomerular filtration rate.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Reference23 articles.

1. The reliability of different formulae to predict creatinine clearance;Verhave;J Intern Med,2003

2. Prediction of creatinine clearance from serum creatinine;Cockcroft;Nephron,1976

3. Estimation of glomerular filtration rate in cancer patients;Wright;Br J Cancer,2001

4. Determination of reference intervals for serum creatinine , creatinine excretion and creatinine clearance with an enzymatic and a modified Jaffe method;Junge;Clin Chim Acta,2004

5. A simple estimate of glomerular filtration rate in children derived from body length and plasma creatinine;Schwartz;Pediatrics,1976

Cited by 22 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3