Stepwise strategies in analysing haematuria and leukocyturia in screening

Author:

Steinmetz Josiane,Henny Joseph,Gueguen René

Abstract

AbstractThe aim of the present work was to compare in a supposed healthy population of 680 subjects several algorithms for positive selection of urine samples requiring microscopic examination for erythrocytes and leukocytes after screening by automated test-strip measurement and particle counting on a Sysmex UF-50™ flow cytometer. Four strategies have been formulated and the sensitivity, specificity, positive predictive value, negative predictive value, false positive rate, false negative rate, and microscopic review rate were measured. The strategy combining test strip analysis and automated counting on all samples, followed by microscopic examination of only discordant samples gave the best results. When the two methods of haematuria screening were in agreement (91% of samples), the false negative rate for microscopy was 1.1%, with a false positive rate of 0.8%, sensitivity of 66% and specificity of 99%, and the results are acceptable without any other examination. When the two methods of haematuria screening were discrepant, visual microscopic analysis was necessary to obtain definitive results. For leukocyturia screening, 80% of results were in agreement by test strip and automatic sediment urinalysis, with only ten results considered as false negatives (1.8%) and four as false positives (0.7%). Agreement was good and the other criteria were good (sensitivity 79%, specificity 99%). On conflicting samples, there was no agreement between methods and microscopic analysis was essential. The benefit of such an algorithm would be optimisation of the workflow without any loss of sensitivity and specificity at the expense of a two-fold increase in cost.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Reference13 articles.

1. Détermination urinaire du glucose des proteines du sang et des leucocytes avec l analyseur automatique Aution Max AX;Steinmetz;Ann Biol Clin,2005

2. De Buyzere ML Automated flow cytometry compared with an automated dipstick reader for urinalysis;Langlois;Clin Chem,1999

3. Routine workflow for use of urine strip and urine flow cytometer UF in the hospital laboratory;Lun;Clin Chem,1999

4. The role of automated urine particle flow cytometry in clinical practice;Delanghe;Clin Chim Acta,2000

5. The automation of sediment urinalysis using a new urine flow cytometer ( UF;Fenili;Clin Chem Lab Med,1998

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3