Evaluation of the BD Vacutainer® PST™ II Blood Collection Tube for special chemistry analytes

Author:

Chance Jeffrey,Berube Julie,Vandersmissen Marita,Blanckaert Norbert

Abstract

Abstract: The performance of the BD Vacutainer: Tubes were drawn by routine venipuncture from 42 subjects according to a randomized draw order. Tubes were processed and centrifuged according to recommended handling procedures. Serum and plasma from the comparison tubes were aliquoted to secondary containers prior to analysis. Specimens were then tested for selected special chemistry analytes at two time intervals (initial time and after 24 h storage). Analytes tested included thyroid stimulating hormone, free thyroxine, total thyroxine, follicle stimulating hormone, luteinizing hormone, ferritin, cortisol, vitamin B12, folate, and testosterone. The data were collected and analyzed by analysis of variance and mean bias comparisons.: The performance of the BD Vacutainer: The BD VacutainerClin Chem Lab Med 2009;47:358–61.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3