Fetal heart examination at the time of 13 weeks scan: a 5 years’ prospective study

Author:

Ebrashy Alaa1ORCID,Aboulghar Mona2,Elhodiby Mohamed3,El-Dessouky Sara H.4,Elsirgany Sherif5,Gaafar Hassan M.2,Sheta Sahar S.6,Kamal Rasha2,Negm Sherif2,El Sheikhah Ahmed2,Idris Omaima2,Abd-el-Kader Mohamed2,Ehab Mohamed2,Momtaz Mohamed2

Affiliation:

1. Fetal Medicine Unit, Department of Obstetrics and Gynecology , Cairo University , Cairo 11435 , Egypt

2. Fetal Medicine Unit, Department of Obstetrics and Gynecology , Cairo University , Cairo , Egypt

3. Department of Obstetrics and Gynecology, Faculty of Medicine , M.U.S.T. University , Cairo , Egypt

4. Prenatal Diagnosis and Fetal Medicine Department, Human Genetics and Genome Research Division, National Research Centre , Cairo , Egypt

5. Reproductive Health Research Department, National Research Centre , Cairo , Egypt

6. Department of Paediatrics , Cairo University , Cairo , Egypt

Abstract

Abstract Objective To evaluate our ability in classifying the fetal heart as normal or abnormal during the 1st trimester scan through fetal cardiac examination and determining the best time for this examination. Methods This was a prospective study performed on 3240 pregnant women to examine the fetal heart. Four chambers view and ventricular outflow tracts were mainly examined during the scan. We used grayscale and color mapping in the diagnosis. Color Doppler was used if additional information was needed, and all patients were rescanned during the 2nd trimester to confirm or negate our diagnosis. Results The cardiac findings were normal at both scans in 3108 pregnancies. The same cardiac abnormality was detected at both scans in 79 cases. In 36 cases there was false-positive diagnosis at the early scan; in 20 of these cases, there were mildly abnormal functional findings early in pregnancy with no abnormality found later. In 17 fetuses, there was discordance between the early and later diagnosis due to missed or incorrect diagnoses. The best time to do fetal heart examination during 1st trimester is between 13 and 13 + 6 weeks. Conclusion A high degree of accuracy in the identification of congenital heart disease (CHD) can be achieved by a 1st trimester fetal echocardiography.

Publisher

Walter de Gruyter GmbH

Subject

Obstetrics and Gynecology,Pediatrics, Perinatology and Child Health

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3