Comparison of automated vs. manual measurement to estimate fetal weight in isolated polyhydramnios

Author:

Eroglu Hasan,Orgul Gokcen,Avcı Emine,Altınboga Orhan,Karakoc Gokhan,Yucel Aykan

Abstract

Abstract Objective To understand the impact of the measurement method to predict actual birthweight in pregnancies complicated with isolated polyhydramnios in the third trimester. Methods A prospective study was conducted with 60 pregnant women between the 37th and 40th weeks of gestation. Routine biometric measurements were obtained by two-dimensional (2D) ultrasonography. When a satisfactory image was obtained, the image was frozen to get two measurements. First, calipers were placed to get the manual measurement. Then automated measurement was captured by the ultrasonography machine in the same image. The fetal weight was estimated by using the Hadlock II formula. Results The mean difference was found to be 0.03, −0.77, −0.02 and 0.17 for biparietal diameter (BPD), head circumference (HC), abdominal circumference (AC) and femur length (FL), respectively. Pearson’s correlation coefficient between automated and manual estimated fetal weights (EFWs) and the actual birthweight was 0.919 and 0.796, respectively. The mean difference between actual and manual EFW measurement values was 46.16 ± 363.81 g (range between −745 g and 685 g) (P = 0.330). Also, the mean difference between actual and automated EFW measurement values was found to be 31.98 ± 218.65 g (range between −378 g and 742 g) (P = 0.262). The Bland-Altman test results have shown that, 666 g lower or 759 g higher values were obtained when the measurement was performed manually. On the other hand, EFW results were 396 g lower or 460 g higher than the actual birthweight with automated measurement tools. Conclusion The accuracy rate of fetal weight estimation with ultrasonography is high for both automated and manual measurements. Automated tools have a higher success to predict the EFW.

Publisher

Walter de Gruyter GmbH

Subject

Obstetrics and Gynaecology,Pediatrics, Perinatology, and Child Health

Reference54 articles.

1. Evaluation of automated tool for 2D fetal biometry;Ultrasound Obstet Gynecol,2018

2. Morbidity and mortality among very-low-birth-weight neonates with intrauterine growth restriction;Am J Obstet Gynecol,2000

3. Automatic measurements of fetal long bones. A feasibility study;J Ultrasound Med,1991

4. Importance of routine ultrasonography in detecting fetal karyotype abnormalities in low risk pregnancies;Gynecol Obstet Reprod Med,2012

5. Automatic fetal head measurements from sonographic images;Acad Radiol,1996

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3