High-frequency operation of a pulsatile VAD – a simulation study

Author:

Rebholz Mathias,Amacher Raffael,Petrou Anastasios,Meboldt Mirko,Schmid Daners Marianne

Abstract

AbstractVentricular assist devices (VADs) are mechanical blood pumps that are clinically used to treat severe heart failure. Pulsatile VADs (pVADs) were initially used, but are today in most cases replaced by turbodynamic VADs (tVADs). The major concern with the pVADs is their size, which prohibits full pump body implantation for a majority of patients. A reduction of the necessary stroke volume can be achieved by increasing the stroke frequency, while maintaining the same level of support capability. This reduction in stroke volume in turn offers the possibility to reduce the pump’s overall dimensions. We simulated a human cardiovascular system (CVS) supported by a pVAD with three different stroke rates that were equal, two- or threefold the heart rate (HR). The pVAD was additionally synchronized to the HR for better control over the hemodynamics and the ventricular unloading. The simulation results with a HR of 90 bpm showed that a pVAD stroke volume can be reduced by 71%, while maintaining an aortic pulse pressure (PP) of 30 mm Hg, avoiding suction events, reducing the ventricular stroke work (SW) and allowing the aortic valve to open. A reduction by 67% offers the additional possibility to tune the interaction between the pVAD and the CVS. These findings allow a major reduction of the pVAD’s body size, while allowing the physician to tune the pVAD according to the patient’s needs.

Publisher

Walter de Gruyter GmbH

Subject

Biomedical Engineering

Reference70 articles.

1. Right ventricular failure – a continuing problem in patients with left ventricular assist device support;J Cardiovasc Transl Res,2010

2. A novel counterpulsation mode of rotary left ventricular assist devices can enhance myocardial perfusion;J Artif Organs,2011

3. A history of devices as an alternative to heart transplantation;Heart Fail Clin,2014

4. Initial results of clinical trial with a new left ventricular assist device (LVAD) providing synchronous pulsatile flow;Int J Artif Organs,2009

5. Initial results of clinical trial with a new left ventricular assist device (LVAD) providing synchronous pulsatile flow;Int J Artif Organs,2009

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3