Abstract
Abstract
In order to investigate the effects of environmental conditions on materials, industrial products or to meet long warranty periods of the products, various tests are performed in the climate test chambers. They have a multidisciplinary structure and should be designed according to different operating conditions. So obtaining the mathematical model of them and knowing the performance of dynamic behavior are significant both in the design phase and in the control of the designed system. In this study, a novel model is developed for numerical investigation of heating process of prototype climatic test due to the mentioned needs. A so-called temperature-dependent L-section line approach was developed. The insulation material was divided into seven segments. The thermal conduction coefficients of the insulation material, mass flow rate, and specific heat of the air were modeled as a function of temperature, as distinct from constant-coefficient lumped-parameter approaches. The simulation results were compared with the experimental results for different conditions, it was observed that the presented approach was compatible with the experimental results. This developed model is not only limited to climate test chambers, but can also be applied to different engineering disciplines such as control, energy, heat and mass transfer, building, and construction.
Publisher
Walter de Gruyter GmbH
Subject
Mechanical Engineering,Mechanics of Materials,General Materials Science
Reference32 articles.
1. M. Friedlein, D. Gräf, J. Stegner, and J. Franke, “Development and application of load profiles for thermal qualification testing of receptacle automotive connectors,” Mater. Test., vol. 63, no. 3, pp. 272–278, 2021, https://doi.org/10.1515/mt-2020-0040. 2. B. Batur, M. C. Çelik, and M. Akgün, “Operating conditions and energy consumption of test rooms produced for various purposes,” in Proc. of the 14th National HVAC&R Congress, Turkey, İzmir, 2019, pp. 355–367 (in Turkish). 3. S. Backens, J. Siering, S. Schmidt, N. Glück, and W. Flügge, “Comparative study of thermoplastic liner materials with regard to mechanical and permeation barrier properties before and after cyclic thermal aging,” Mater. Test., vol. 63, no. 4, pp. 311–316, 2021, https://doi.org/10.1515/mt-2020-0051. 4. H. Bayram, “Climatic chamber with chassis dynamometer testing simulator car model development and validation process,” Uludağ Univ. J. Faculty Eng., vol. 21, no. 2, pp. 451–464, 2016 (in Turkish), https://doi.org/10.17482/uumfd.285461. 5. C. Strangfeld and S. Kruschwitz, “Determination of readiness for laying based on material moisture, corresponding relative humidity, and water release,” Mater. Test., vol. 62, no. 10, pp. 1033–1040, 2020, https://doi.org/10.3139/120.111581.
|
|