Affiliation:
1. Institut für Physikalische Elektronik der Universität Stuttgart
Abstract
Abstract
The radial temperature distribution in a Hg-high-pressure discharge with metal halogene additives (Sn-, Zn-Iodide) has been measured. Three different spectroscopic methods (Emission-, Absorption-, Bartels-and 2-lines-Method) are compared. The influence of the silica bulb is discussed. High incidence angles for the absorption measurements are realized by use of an elliptic mirror. Emission and absorption measurements in a definite time intervall of the 50 Hz-discharge current was done with signal averaging technique. The arc shows a constriction which is discussed.
Subject
Physical and Theoretical Chemistry,General Physics and Astronomy,Mathematical Physics
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献