Combined international external quality assessment results of medical laboratory performance and reporting of samples with known antimicrobial resistance

Author:

Noble Michael A.1,Rennie Robert2

Affiliation:

1. Clinical Microbiology Proficiency Testing (CMPT), Department of Pathology and Laboratory Medicine , University of British Columbia , G-409, 2211 Wesbrook Mall , Vancouver, British Columbia , Canada

2. Department of Pathology and Laboratory Medicine , University of Alberta , Edmonton, Alberta , Canada

Abstract

Abstract Background Reporting on the presence of antimicrobial resistance is of considerable concern both for individual patient care and for understanding the underlying health status within the community at large. Antimicrobial resistance is solely dependent upon clinical laboratory detection and thus can be impacted upon by the quality and competence of medical laboratories. Proficiency testing or external quality assessment (PT/EQA) is the international standard for the direct measurement of medical laboratory performance on critical testing. Methods An international, intercontinental collaborative retrospective study of medical laboratory performance in antibiotic resistance was performed by the Microbiology Working Group (MWG) of the European Organisation for External Quality Assurance for Laboratory Medicine (EQALM) with particular examination of laboratory performance on the testing and reporting of methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant enterococci (VRE) and carbapenem-resistant Enterobacteriaceae (CRE). Results The results of 1880 medical laboratories were compiled. Strictly accurate reporting of isolates as resistant occurred with MRSA 96.9%, with VRE 91.3% and with CRE 93.1% of the time. On the other hand, very major errors (reporting of false susceptibility) were observed with 2.2% of MRSA and 2.4% of VRE and 0.8% of CRE. Major errors (false resistance) were reported for vancomycin susceptibility testing for MRSA at a rate of 0.6%. Conclusions Depending on how clinical physicians read and understand microbiology susceptibility reports, proficient acceptable results were reported either between 91% and 94% of the time, or between 97% and 100%. While very major errors are infrequently reported, they were found in all regions and could potentially cause poor treatment decisions by clinicians. A collective analysis of multi-program PT/EQA information can provide valuable insights into the testing and reporting practices of medical laboratories.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,Public Health, Environmental and Occupational Health,Health Policy,Medicine (miscellaneous)

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3