Electroencephalographic changes associated with non-invasive nociceptive stimulus in minimally anaesthetised dogs

Author:

Kaka U.,Goh Y.M.,Chean L.W.,Chen H.C.

Abstract

Abstract Electroencephalography (EEG) has been reported as an objective, non-invasive and stress free technique for nociceptive studies. Electrical stimuli can be used to evaluate the efficacy of centrally acting agents. Peripheral nerve stimulator can be a good and cheap source of electric stimulus for studies of nociception, and studies evaluating analgesic effect of drugs under EEG. In this study suitability of peripheral nerve stimulator, and milliamperage for nociceptive studies under electroencephalography were evaluated. Six dogs were subjected to electric stimulus of 20, 40, 60 and 80 milliamperes (mAs) before and after tramadol administration at 4 mg/kg IV. Electroencephalograph was recorded during electric stimulus prior tramadol (pre-tramadol) and during electric stimulus after tramadol (post-tramadol) under minimal anaesthesia. Anaesthesia was induced with propofol and maintained with halothane at a stable concentration between 0.85 and 0.95%. Pre-tramadol median frequency (MF) increased significantly (p<0.05) at 40, 60 and 80 mAs post-electric stimulus compared to baseline MF. No difference in pre-tramadol MF was observed between 60 and 80 mAs. Tramadol produced significant effect by depression of MF at all intensities. The effect was less evident at 80 mAs. The results revealed that tramadol produced evident effect between 20 and 60 mAs. Thus, it is concluded that nerve stimulator can be used with the current between 20 and 60 mAs for nociceptive studies.

Publisher

Walter de Gruyter GmbH

Subject

General Veterinary,General Medicine

Reference60 articles.

1. Electrophysiology of opioids;Duggan;Pharmacol Rev,1984

2. Electroencephalography during ovariohysterectomy in rats anaesthetized with halothane Vet;Murrell,2010

3. Electroencephalographic responses of tramadol parecoxib and morphine to acute noxious electrical stimulation in anaesthetised dogs;Kongara;Res Vet Sci,2010

4. NA Comparison of analgesic techniques for antler removal in halothane anaesthetized red deer elaphus electroencephalographic responses;Johnson;Vet Anaesth Analg,2005

5. MR NA PR Comparison of analgesic techniques for antler removal in halothane anaesthetized red deer elaphus cardiovascular and somatic responses;Woodbury;Vet Anaesth Analg,2005

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3