Abstract
The modulus optimum (MO) criterion can be used for analytical design of the PID controller for linear systems with dominant dead time. However, although the method usually gives fast and non-oscillating closed-loop responses, in the case of large dead time the stability margin gets reduced and even non-stable behavior can be observed. In this case a correction of the settings is needed to preserve the stability margin. We describe and compare two methods of design of the PID controller based on the MO criterion that for the stable first-order systems with dead time preserve the stability margin, trying to keep maximum of the performance of the original MO settings.
Subject
Control and Optimization,Modeling and Simulation,Control and Systems Engineering
Reference9 articles.
1. A magnitude optimum multiple integration tuning method for filtered PID controller;VRANCIĆ;Automatica,2001
2. A new PID controller tuning method based on multiple integrations;VRANCIĆ;Control Engineering Practice,1999
3. Design of PI controllers based on non - convex optimization;ÅSTRÖM;Automatica,1998
4. A uniform approach to the optimum adjustments of control loops of the ASME;OLDENBOURG;Trans,1954
5. On the automatic control of generalized passive systems of the ASME;CHIEN;Trans,1952
Cited by
7 articles.
订阅此论文施引文献