Affiliation:
1. “Carol Davila” University of Medicine and Pharmacy , Bucharest , Romania
2. “Cantacuzino” National Institute of Research , Bucharest , Romania
Abstract
Abstract
Introduction. Two cases of circulating vaccine-derived poliovirus type 1(cVDPV1), from southwestern Ukraine, bordering Romania, were confirmed in 2015 and the environmental enterovirus surveillance was enhanced in our country. The molecular detection of human enteroviruses as a screening test followed by isolation on cell culture lines or sequencing could be proposed as a new diagnosis algorithm.
Material and Methods. The sensitivity of two molecular methods for the detection of enterovirus strains in 10 mL of sewage water (15 samples) was studied with Film Array ME panel BioFire (Biomerieux, France) and Xpert EV assay (Cepheid, USA). These are standardized methods for the detection of microorganisms in the cerebrospinal fluid (CSF).
Results. Of the 15 samples, six enterovirus strains were detected using Film Array ME, four enterovirus strains were detected using Xpert EV assay, while only two nonpolio enterovirus strains were isolated on RD cell line, using the standard WHO algorithm. However, only one of the strains detected by the standard WHO algorithm was detected by one of the molecular methods.
Conclusions. The molecular methods for enterovirus detection are more sensitive than the virus isolation on cell culture lines, but in one case the virus isolated on RD cell line was not detected by the molecular methods. The results could be influenced by the small number of the samples investigated, by the volume and the concentration method used for samples tested, and by the limits of detection (LoD) of the enterovirus species in the samples, depending on the method used.
Reference8 articles.
1. 1. WORLD HEALTH ORGANIZATION. Polio Eradication & Endgame Strategic Plan 2013-2018. (WHO/POLIO/13.02). 2013. Available online http://www.polioeradication.org/resourcelibrary/strategyandwork.aspx.
2. 2. COMBIESCU M, GUILLOT S, PERSU A, BAICUS A, PITIGOI D, BALANANT J, et al. Circulation of a type 1 recombinant vaccine-derived poliovirus strain in a limited area in Romania. Arch. Virol. 2007; 152:727-38.
3. 3. BAICUS A, PERSU A, DINU S, JOFFRET ML, DELPEYROUX F, OPRISAN G. The frequency and biodiversity of poliovirus and non-polio enterovirus strains isolated from healthy children living in a limited area in Romania. Arch Virol. 2011; 156 (4):701-6.
4. 4. EUROPEAN CENTRE FOR DISEASE PREVENTION AND CONTROL. Outbreak of vaccine-derived poliovirus type 1 (cVDPV1) in Ukraine, 2015. August 2015 – 2 September, Stockholm.
5. 5. BAICUS A. Could the GeneXpert system be a new tool for poliovirus detection in the sewage water? Roum Arch Microbiol Immunol. 2016. (1-2):52-4.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献