The integration of the molecular methods in the diagnosis algorithm for the poliovirus detection in the sewage water: comparing concentration and detection methods. A Pilot Study

Author:

Băicuş Anda12

Affiliation:

1. “Carol Davila” University of Medicine and Pharmacy , Bucharest , Romania

2. “Cantacuzino” National Institute of Research , Bucharest , Romania

Abstract

Abstract Introduction. Two cases of circulating vaccine-derived poliovirus type 1(cVDPV1), from southwestern Ukraine, bordering Romania, were confirmed in 2015 and the environmental enterovirus surveillance was enhanced in our country. The molecular detection of human enteroviruses as a screening test followed by isolation on cell culture lines or sequencing could be proposed as a new diagnosis algorithm. Material and Methods. The sensitivity of two molecular methods for the detection of enterovirus strains in 10 mL of sewage water (15 samples) was studied with Film Array ME panel BioFire (Biomerieux, France) and Xpert EV assay (Cepheid, USA). These are standardized methods for the detection of microorganisms in the cerebrospinal fluid (CSF). Results. Of the 15 samples, six enterovirus strains were detected using Film Array ME, four enterovirus strains were detected using Xpert EV assay, while only two nonpolio enterovirus strains were isolated on RD cell line, using the standard WHO algorithm. However, only one of the strains detected by the standard WHO algorithm was detected by one of the molecular methods. Conclusions. The molecular methods for enterovirus detection are more sensitive than the virus isolation on cell culture lines, but in one case the virus isolated on RD cell line was not detected by the molecular methods. The results could be influenced by the small number of the samples investigated, by the volume and the concentration method used for samples tested, and by the limits of detection (LoD) of the enterovirus species in the samples, depending on the method used.

Publisher

Walter de Gruyter GmbH

Reference8 articles.

1. 1. WORLD HEALTH ORGANIZATION. Polio Eradication & Endgame Strategic Plan 2013-2018. (WHO/POLIO/13.02). 2013. Available online http://www.polioeradication.org/resourcelibrary/strategyandwork.aspx.

2. 2. COMBIESCU M, GUILLOT S, PERSU A, BAICUS A, PITIGOI D, BALANANT J, et al. Circulation of a type 1 recombinant vaccine-derived poliovirus strain in a limited area in Romania. Arch. Virol. 2007; 152:727-38.

3. 3. BAICUS A, PERSU A, DINU S, JOFFRET ML, DELPEYROUX F, OPRISAN G. The frequency and biodiversity of poliovirus and non-polio enterovirus strains isolated from healthy children living in a limited area in Romania. Arch Virol. 2011; 156 (4):701-6.

4. 4. EUROPEAN CENTRE FOR DISEASE PREVENTION AND CONTROL. Outbreak of vaccine-derived poliovirus type 1 (cVDPV1) in Ukraine, 2015. August 2015 – 2 September, Stockholm.

5. 5. BAICUS A. Could the GeneXpert system be a new tool for poliovirus detection in the sewage water? Roum Arch Microbiol Immunol. 2016. (1-2):52-4.

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3