Indirect determination of hematology reference intervals in adult patients on Beckman Coulter UniCell DxH 800 and Abbott CELL-DYN Sapphire devices

Author:

Zierk Jakob,Arzideh Farhad,Haeckel Rainer,Rauh Manfred,Metzler Markus,Ganslandt ThomasORCID,Krause Stefan W.

Abstract

Abstract Background Conventional establishment of reference intervals for hematological analytes is challenging due to the need to recruit healthy persons. Indirect methods address this by deriving reference intervals from clinical laboratory databases which contain large datasets of both physiological and pathological test results. Methods We used the “Reference Limit Estimator” (RLE) to establish reference intervals for common hematology analytes in adults aged 18–60 years. One hundred and ninety-five samples from 44,519 patients, measured on two different devices in a tertiary care center were analyzed. We examined the influence of patient cohorts with an increasing proportion of abnormal test results, compared sample selection strategies, explored inter-device differences, and analyzed the stability of reference intervals in simulated datasets with varying overlap of pathological and physiological test results. Results Reference intervals for hemoglobin, hematocrit, red cell count and platelet count remained stable, even if large numbers of pathological samples were included. Reference intervals for red cell indices, red cell distribution width and leukocyte count were sufficiently stable, if patient cohorts with the highest fraction of pathological samples were excluded. In simulated datasets, estimated reference limits shifted, if the pathological dataset contributed more than 15%–20% of total samples and approximated the physiological distribution. Advanced sample selection techniques did not improve the algorithm’s performance. Inter-device differences were small except for red cell distribution width. Conclusions The RLE is well-suited to create reference intervals from clinical laboratory databases even in the challenging setting of a adult tertiary care center. The procedure can be used as a complement for reference interval determination where conventional approaches are limited.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry, medical,Clinical Biochemistry,General Medicine

Reference36 articles.

1. Pediatric reference intervals for alkaline phosphatase;Clin Chem Lab Med,2017

2. Reference limits of plasma and serum creatinine concentrations from intra-laboratory data bases of several German and Italian medical centres: comparison between direct and indirect procedures;Clin Chim Acta,2010

3. The definition of anemia: what is the lower limit of normal of the blood hemoglobin concentration?;Blood,2006

4. Indirect methods for reference interval determination – review and recommendations;Clin Chem Lab Med,2018

5. Critical comments to a recent EFLM recommendation for the review of reference intervals;Clin Chem Lab Med,2017

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3