Abstract
AbstractBackground:Biological variation (BV) data have many fundamental applications in laboratory medicine. At the 1st Strategic Conference of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) the reliability and limitations of current BV data were discussed. The EFLM Working Group on Biological Variation is working to increase the quality of BV data by developing a European project to establish a biobank of samples from healthy subjects to be used to produce high quality BV data.Methods:The project involved six European laboratories (Milan, Italy; Bergen, Norway; Madrid, Spain; Padua, Italy; Istanbul, Turkey; Assen, The Netherlands). Blood samples were collected from 97 volunteers (44 men, aged 20–60 years; 43 women, aged 20–50 years; 10 women, aged 55–69 years). Initial subject inclusion required that participants completed an enrolment questionnaire to verify their health status. The volunteers provided blood specimens once per week for 10 weeks. A short questionnaire was completed and some laboratory tests were performed at each sampling consisting of blood collected under controlled conditions to provide serum, KResults:Samples from six out of the 97 enroled subjects were discarded as a consequence of abnormal laboratory measurements. A biobank of 18,000 aliquots was established consisting of 120 aliquots of serum, 40 of EDTA-plasma, and 40 of citrated-plasma from each subject. The samples were stored at –80 °C.Conclusions:A biobank of well-characterised samples collected under controlled conditions has been established delivering a European resource to enable production of contemporary BV data.
Subject
Biochemistry (medical),Clinical Biochemistry,General Medicine
Reference48 articles.
1. Common reference intervals for aspartate aminotransferase (AST), alanine aminotransferase (ALT) and γ-glutamyl transferase (GGT) in serum: results from an IFCC multicenter study;Clin Chem Lab Med,2010
2. http www westgard com biodatabase htm Accessed Jan,2016
3. http www eflm eu index php wg biological variation html Accessed Jan,2016
4. Circannual temperature-related variation in hemoglobin A1c is unlikely to affect its use as a diagnostic test for type 2 diabetes;Clin Lab,2012
5. Individual character of variation in time-series studies of healthy people II. Differences in values for clinical chemical analytes in serum among demographic groups, by age and sex;Clin Chem,1978
Cited by
90 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献