Determination of sigma score based on biological variation for haemostasis assays: fit-for-purpose for daily practice?

Author:

Hollestelle Martine J.,Ruinemans-Koerts Janneke,Idema René N.,Meijer Piet,de Maat Moniek P.M.

Abstract

Abstract Background Internal quality control (QC) rules for laboratory tests can be derived from analytical performance specifications (APS) using the six-sigma method. We tested the applicability of this paradigm to routine haemostasis measurements. Methods Three laboratories using different instruments and reagents calculated sigma scores for their prothrombin time (PT), activated partial thromboplastin time (APTT), fibrinogen and antithrombin (AT) measurements. Sigma scores were calculated using biological variation (BV) data from the literature in combination with internal and external QC data. Results Wide ranges in sigma scores for the PT (0.1–6.8), APTT (0.0–4.3), fibrinogen (1.5–8.3) and AT (0.1–2.4) were observed when QC data was combined with the minimum, median and maximum value of BV data, due in particular to a large variation in within-subject and between-subjects coefficients of variation. When the median BV values were applied, most sigma scores were below 3.0, for internal QC data; 75% and for external QC data; 92%. Conclusions Our findings demonstrate that: (1) The sigma scores for common haemostasis parameters are relatively low, and (2) The application of the six-sigma method to BV-derived APS is hampered by the large variation in published BV data. As the six-sigma concept is based on requirements for monitoring, and many haemostasis tests are only designed for diagnostic purposes, a fit-for-purpose APS is needed to achieve clinically relevant quality goals.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry, medical,Clinical Biochemistry,General Medicine

Reference76 articles.

1. Analytical and biologic variability in measures of hemostasis, fibrinolysis, and inflammation: assessment and implications for epidemiology;Am J Epidemiol,1999

2. Proposed goals for analytical precision and accuracy in single-point diagnostic testing. Theoretical basis and comparison with data from College of American Pathologists proficiency surveys;Arch Pathol Lab Med,1988

3. The use of error and uncertainty methods in the medical laboratory;Clin Chem Lab Med,2018

4. Sources of variability in coagulation factor assays;Thromb Haemost,1987

5. State of the art vs. biological variability: comparison on hematology parameters using Spanish EQAS data;Int J Lab Hematol,2018

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3