Influence of pneumatic tube system transport on routinely assessed and spectrophotometric cerebrospinal fluid parameters

Author:

Broz Pavel,Rajdl Daniel,Racek Jaroslav,Zenkova Jana,Petrikova Vlasta

Abstract

Abstract Background: Pneumatic tube systems (PTS) are widely used in many hospitals. Using PTS reduces turnaround time (TAT) and can improve patients’ outcome. Methods: We investigated whether clinically significant differences could be observed in CSF samples transported by pneumatic tube in comparison with samples transported by hand. Two aliquots from one sample were sent by PTS and by hand from the department of neurology or neurosurgery and compared. Results: Routine cytological and biochemical assessment was compared in 27 cases. There were no statistically significant changes (transport by hand vs. PTS) in glucose levels [data are expressed as median (minimum–maximum)] at 3.7 (2.5–8.6) mmol/L vs. 3.6 (2.7–8.6) mmol/L, p=0.96 or lactate levels at 1.8 mmol/L (1.1–5.5) vs. 1.8 mmol/L (1.1–5.4). We observed a statistically significant decline in total protein levels in samples transported by PTS at 0.56 g/L (0.19–4.29) vs. 0.49 g/L (0.18–4.3), p=0.008. We observed no changes in erythrocyte count at 5/μL (0–40,000) vs. 5/μL (0–40,106), mononuclear cells at 2/μL (1–145) vs. 3/μL (1–152), or polynuclear cells at 0/μL (0–235) vs. 0/μL (0–352). Spectrophotometric examination was performed in 20 cases. There were no statistically significant differences (transport by hand vs. transport by PTS) in NOA at 0.002 (0.001–1.537) vs. 0.001 (0.001–1.528), p=0.95 or NBA at 0.001 (0.001–0.231) vs. 0.001 (0.001–0.276), p=0.675. Samples transported by PTS were delivered faster than samples transported by courier (transport by hand vs. PTS) at 25 min (10–153) vs. 15 min (4–110), p=0.002. Conclusions: We found no significant changes in glucose, lactate levels and in any of the cytological parameters assessed, nor were statistically significant changes observed in the spectrophotometric parameters. We found a statistically significant decrease in total protein levels in samples transported by PTS. Transport by PTS can be faster than transport by hand.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3