Author:
Fahim Magid A.,Hayen Andrew D.,Horvath Andrea R.,Dimeski Goce,Coburn Amanda,Tan Ken-Soon,Johnson David W.,Craig Jonathan C.,Campbell Scott B.,Hawley Carmel M.
Abstract
AbstractChanges in high sensitivity cardiac troponin-T (hs-cTnT) concentrations may reflect either acute myocardial injury or biological variation. Distinguishing between these entities is essential to accurate diagnosis, however, the biological variation of hs-cTnT in dialysis population is currently unknown. We sought to estimate the within- and between-person coefficients of variation of hs-cTnT in stable dialysis patients, and derive the critical difference between measurements needed to exclude biological variation with 99% confidence.Fifty-five prevalent haemo- and peritoneal-dialysis patients attending two metropolitan hospitals were assessed on 10 consecutive occasions; weekly for 5 weeks then monthly for 4 months. Assessments were conducted at the same dialysis cycle time-point and entailed hs-cTnT testing, clinical review, electrocardiography, and bioimpedance spectroscopy. Patients were excluded if they developed clinical or physiological instability.In total 137 weekly and 114 monthly hs-cTnT measurements from 42 stable patients were analysed. Respective between- and within-person coefficients of variation were 83% and 7.9% for weekly measurements, and 79% and 12.6% for monthly measurements. Within-person variation was unaffected by dialysis modality or cardiac co-morbidity. The bidirectional 99% reference change value was –25% and +33% for weekly measurements, and –37% and +58% for monthly measurements.The between-person variation of hs-cTnT in the dialysis population is markedly greater than within-person variation indicating that hs-cTnT testing is best applied in this population using a relative change strategy. An increase of 33% or a reduction of 25% in serial hs-cTnT concentrations measured at weekly intervals excludes change due to analytical and biological variation alone with 99% confidence.
Subject
Biochemistry, medical,Clinical Biochemistry,General Medicine
Reference66 articles.
1. de CM Preanalytical storage does not affect th percentile cardiac troponin T concentrations measured with a high - sensitivity assay;Gillis;Clin Chem,2013
2. High - sensitivity cardiac troponin T for early prediction of evolving non - ST - segment elevation myocardial infarction in patients with suspected acute coronary syndrome and negative troponin results on admission;Giannitsis;Clin Chem,2010
3. Cardiac diseases in maintenance hemodialysis patients : results of the HEMO Study;Cheung;Kidney Int,2004
4. The epidemiology of heart failure the Study;Ho;J Am Coll Cardiol,1993
5. Influence of sampling time and ultrafiltration coefficient of the dialysis membrane on cardiac troponin;Lippi;Arch Pathol Lab Med,2008
Cited by
28 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献