Quantification of vanillylmandelic acid, homovanillic acid and 5-hydroxyindoleacetic acid in urine using a dilute-and-shoot and ultra-high pressure liquid chromatography tandem mass spectrometry method

Author:

Grouzmann Eric1,Centeno Catherine1,Eugster Philippe J.1

Affiliation:

1. Laboratoire des Catecholamines et Peptides, Service de Pharmacologie Clinique , Centre Hospitalier Universitaire Vaudois , Lausanne , Switzerland

Abstract

Abstract Background: Urinary vanillylmandelic acid (VMA) and homovanillic acid (HVA) are biomarkers for the diagnosis and follow-up of neuroblastoma, whereas urinary 5-hydroxyindoleacetic acid (5-HIAA) is used to assess a carcinoid tumor. These analytes are conventionally analyzed in a single run by chromatography (LC) coupled with electrochemical detection (LC-ECD) using commercial kits. A rapid dilute-and-shoot LC tandem mass spectrometry (LC-MS/MS) assay was validated in order to replace the LC-ECD method and therefore improve analytical specificity and throughput. Methods: Sample preparation was carried out by dilution of the urine sample with a solution containing the deuterated internal standards. The separation was achieved on an ultra-high pressure LC system with MS detection using a triple quadrupole mass spectrometer. The method was validated according to the current EMA and FDA guidelines. Results: The full chromatographic run was achieved in 8 min. The method validation showed excellent linearity (r2>0.999 for all three analytes), precision (CV <15%), negligible matrix effect (recoveries >90%), low carryover (<1%) and LLOQ of 0.25, 0.4 and 0.4 μM for VMA, HVA and 5-HIAA, respectively. Deming fits and Bland-Altman analyses showed no significant differences between the values obtained between the two assays. Conclusions: The LC-MS/MS method proposed in this study is fast and robust, and the simple sample preparation saves time and avoids the additional costs of dedicated kits used for the LC-ECD assays by switching to LC-MS/MS. Additionally, the near-perfect correlation observed herein between both assays allows the previously established reference ranges to be maintained.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry, medical,Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3