Use of quality indicators to compare point-of-care testing errors in a neonatal unit and errors in a STAT central laboratory

Author:

Cantero Miguel,Redondo Maximino,Martín Eva,Callejón Gonzalo,Hortas María Luisa

Abstract

AbstractPoint-of-care testing (POCT), like other laboratory tests, can be affected by errors throughout the total testing process. To evaluate quality error rates, the use of quality indicators (QIs) is recommended; however, little information is available on the quality error rate associated with POCT. The objective of this study was to investigate quality error rates related to POCT and compare them with central laboratory (CL) testing.We studied standardized QIs for POCT in comparison to CL testing. We compared error rates related to requests, collection, and handling of samples and results from external quality assessment program (EQAP) and internal quality control (IQC).The highest difference between POCT and CL testing was observed for QI related to patient identification, 45.3% vs. 0.02% (p<0.001). Regarding specimen collection and handling, the QI related to samples without results was also higher in POCT than in CL testing, 15.8% vs. 3.3% (p<0.001). For the QI related to insufficient sample volume, we obtained 2.9% vs. 0.9% (p=0.27). Unlike QIs for the preanalytical phase, QIs for the analytical phase had better results in POCT than CL testing. We obtained 8.3% vs. 16.6% (p=0.13) for QI related to unacceptable results in EQAP and 0.8% vs. 22.5% (p<0.001) for QI related to unacceptable results in IQC.Our results show that the preanalytical phase remains the main problem in POCT like in CL testing and that monitoring of quality indicators is a very valuable tool in reducing errors in POCT.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Reference54 articles.

1. The IFCC Working Group on laboratory errors and patient safety;Sciacovelli;Clin Chim Acta,2009

2. SS Plan for quality to improve patient safety at the point of care;Ehrmeyer;Ann Saudi Med,2011

3. Da WG Quality indicators in laboratory medicine from theory to practice Preliminary data from the IFCC Working Group Project Laboratory Errors and Patient Safety;Sciacovelli;Clin Chem Lab Med,2011

4. Da WG Quality indicators in laboratory medicine from theory to practice Preliminary data from the IFCC Working Group Project Laboratory Errors and Patient Safety;Sciacovelli;Clin Chem Lab Med,2011

5. Biological variation database and quality specifications for imprecision bias and total error The update Available from http www seqc es Accessed on;March,2012

Cited by 24 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. The influence of undetected hemolysis on POCT potassium results in the emergency department;Clinical Chemistry and Laboratory Medicine (CCLM);2024-05-13

2. Evaluación de riesgos en el manejo de equipos para Point-of-Care Testing de ámbito hospitalario. Revisión sistemática;Medicina y Laboratorio;2023-09-21

3. Planning education for best practices in point-of-care testing;Turkish Journal of Biochemistry;2022-07-08

4. Los errores en las pruebas de cabecera pueden resultar en falsos niveles de potasio;Advances in Laboratory Medicine / Avances en Medicina de Laboratorio;2022-03-01

5. Point-of-Care Biosensors for Glucose Sensing;Nanobiosensors for point-of-care medical diagnostics;2022

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3