Affiliation:
1. Laboratory of Clinical Biochemistry, Department of Life and Reproduction Sciences, University of Verona , Verona , Italy
2. U.O. Diagnostica Ematochimica, Azienda Ospedaliero-Universitaria di Parma, Via Gramsci, 14, 43126 Parma, Italy
Abstract
Abstract
Background: The potential for cross-contamination of additives among evacuated blood tubes has led to the development of the order of draw. This practice, however, is mainly based on scarce, anecdotal, and mostly outdated literature data. Therefore, the goal of this investigation was to definitely establish whether or not the indication of a specific order of draw is still justified.
Methods: The study population consisted of 57 outpatients referred to the outpatient oral anticoagulant (OA) clinic of the Academic Hospital of Verona and 58 healthy volunteers enrolled from the laboratory personnel. In OA outpatients, one serum tube was collected immediately after needle insertion, followed by a buffered sodium citrate tube and another serum tube. In the healthy volunteers, one serum tube was collected immediately after needle insertion, followed by a potassium-ethylenediaminetetraacetic acid (K2-EDTA) tube and another serum tube. After separation, the serum was tested for potassium, sodium, calcium, magnesium, and phosphorus in the first and second serum tubes.
Results: No significant difference could be observed between the first and the second serum tubes for any of the parameters. The bias calculated with Bland-Altman plots did not achieve statistical significance when the serum tube was collected after either a K2-EDTA or a sodium citrate tube.
Conclusions: According to our data, revision of national and supranational recommendations on blood collection by venipuncture should consider that the order of draw exerts a negligible effect on sample quality, and this aspect should no longer be considered a quality criterion when evaluating the performance of phlebotomists.
Subject
Biochemistry (medical),Clinical Biochemistry,General Medicine
Reference19 articles.
1. Lippi G, Salvagno GL, Montagnana M, Lima-Oliveira G, Guidi GC, Favaloro EJ. Quality standards for sample collection in coagulation testing. Semin Thromb Hemost 2012;38:565–75.22669757http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=000308401300004&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=b7bc2757938ac7a7a821505f8243d9f3
2. Lippi G, Becan-McBride K, Behúlová D, Bowen RA, Church S, Delanghe J, et al. Preanalytical quality improvement: in quality we trust. Clin Chem Lab Med 2013;51:229–41.23072858http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=000312497600023&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=b7bc2757938ac7a7a821505f8243d9f3
3. Lima-Oliveira G, Lippi G, Salvagno GL, Montagnana M, Manguera CL, Sumita NM, et al. New ways to deal with known preanalytical issues: use of transilluminator instead of tourniquet for easing vein access and eliminating stasis on clinical biochemistry. Biochem Med (Zagreb) 2011;21:152–9.10.11613/BM.2011.024
4. Lippi G, Plebani M. Primary blood tubes mixing: time for updated recommendations. Clin Chem Lab Med 2012;50:599–600.22505555http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=000304337100002&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=b7bc2757938ac7a7a821505f8243d9f3
5. Adcock Funk DM, Lippi G, Favaloro EJ. Quality standards for sample processing, transportation, and storage in hemostasis testing. Semin Thromb Hemost 2012;38:576–85.22706973http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=000308401300005&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=b7bc2757938ac7a7a821505f8243d9f3
Cited by
36 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献