Accuracy and precision assessment of a new blood glucose monitoring system

Author:

Ji Li-Nong,Guo Li-Xin,Liu Li-Bin

Abstract

AbstractBlood glucose self-monitoring by individuals with diabetes is essential in controlling blood glucose levels. The International Organization for Standardization (ISO) introduced new standards for blood glucose monitoring systems (BGMS) in 2013 (ISO 15197: 2013). The CONTOUR PLUSThis study evaluated the accuracy and precision of CONTOUR PLUS BGMS in quantitative glucose testing of capillary and venous whole blood samples obtained from 363 patients at three different hospitals.Results of fingertip and venous blood glucose measurements by the CONTOUR PLUS system were compared with laboratory reference values to determine accuracy. Accuracy was 98.1% (96.06%–99.22%) for fingertip blood tests and 98.1% (96.02%–99.21%) for venous blood tests. Precision was evaluated across a wide range of blood glucose values (5.1–17.2 mmol/L), testing three blood samples repeatedly 15 times with the CONTOUR PLUS blood glucose meter using test strips from three lots. All within-lot results met ISO criteria (i.e., SD<0.42 mmol/L for blood glucose concentration <5.55 mmol/L; CV<7.5% for blood glucose concentration ≥5.55 mmol/L). Between-lot variations were 1.5% for low blood glucose concentration, 2.4% for normal and 3.4% for high.Accuracy of both fingertip and venous blood glucose measurements by the CONTOUR PLUS system was >95%, confirming that the system meets ISO 15197: 2013 requirements.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Reference24 articles.

1. for Standardization ISO In vitro diagnostic test systems requirements for blood glucose monitoring systems for self - testing in managing diabetes mellitus for Standardization;Geneva;International Organization International Organization,2003

2. for Standardization ISO In vitro diagnostic test systems requirements for blood glucose monitoring systems for self - testing in managing diabetes mellitus for Standardization;Geneva;International Organization International Organization,2013

3. Performance evaluation and labeling comprehension of a new blood glucose monitoring system with integrated information;List;management Diabetes Sci Technol,2011

4. Platten Accuracy of self monitoring blood glucose systems in a clinical setting : application of new planned ISO - standards;Hasslacher;Clin Lab,2013

5. Performance evaluation and labeling comprehension of a new blood glucose monitoring system with integrated information;List;management Diabetes Sci Technol,2011