Various glycolysis inhibitor-containing tubes for glucose measurement cannot be used interchangeably due to clinically unacceptable biases between them

Author:

Saracevic Andrea1,Dukic Lora2,Juricic Gordana3,Milevoj Kopcinovic Lara4,Mirosevic Gorana5,Simundic Ana-Maria2

Affiliation:

1. Department of Medical Laboratory Diagnostics , University Hospital “Sveti Duh” , Sveti Duh 64 , Zagreb , Croatia , Phone: +385 1 3712 117

2. Department of Medical Laboratory Diagnostics , University Hospital “Sveti Duh” , Zagreb , Croatia

3. Department of Laboratory Diagnostics , General Hospital Pula , Pula , Croatia

4. University Department of Chemistry, University Hospital Center “Sestre Milosrdnice” , Zagreb , Croatia

5. Department of Endocrinology, Diabetology and Metabolic diseases “Mladen Sekso” , University Hospital Center “Sestre Milosrdnice” , Zagreb , Croatia

Abstract

Abstract Background: The aim of our study was to determine the difference between glucose concentration measured 30 min after venipuncture in ice-chilled heparin plasma sample and all currently available citrate buffer-containing tubes (Greiner Glucomedics, Greiner FC Mix and Sarstedt GlucoEXACT) and still widely used sodium fluoride/potassium oxalate (NaF/Kox) tubes from Greiner. Methods: Blood was collected from 20 healthy volunteers and 20 patients with diabetes into LiH, NaF/KOx, Glucomedics, FC mix and GlucoEXACT tubes. Glucose was measured within 30 min from blood sampling in duplicate on the Architect c8000 analyzer. Mean biases between all tube types were calculated and compared to the recommended criteria (1.95%). Additionally, glucose concentrations measured in all five tube types were compared using the Friedman test. Results: In the entire studied population, glucose concentrations measured in Glucomedics, FC mix and GlucoEXACT were higher (7.3%, 3.2% and 2.0%, respectively) than in the ice-chilled LiH tubes. When all glycolysis inhibitor-containing tubes were compared, Glucomedics tubes significantly differed from GlucoEXACT and FC mix tubes (biases −4.9% and 4.0%, respectively). In addition, there was a significant difference between the NaF/KOx tube and Glucomedics, as well as FC mix tubes (biases 7.1% and 3.0%, respectively). Conclusions: Glucose concentrations measured in recommended ice-chilled lithium heparin- and citrate buffer-containing tubes are not comparable. Significant biases exist between various glycolysis inhibitor-containing tubes; therefore, they cannot be used interchangeably.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry, medical,Clinical Biochemistry,General Medicine