Affiliation:
1. Department of Laboratory Medicine , University-Hospital of Padova , Padova , Italy
Abstract
Abstract
The recently raised concerns regarding biotin interference in immunoassays have increased the awareness of laboratory professionals and clinicians of the evidence that the analytical phase is still vulnerable to errors, particularly as analytical interferences may lead to erroneous results and risks for patient safety. The issue of interference in laboratory testing, which is not new, continues to be a challenge deserving the concern and interest of laboratory professionals and clinicians. Analytical interferences should be subdivided into two types on the basis of the possibility of their detection before the analytical process. The first (type 1) is represented by lipemia, hemolysis and icterus, and the second (type 2), by unusual constituents that are not undetectable before analysis, and may affect the matrix of serum/plasma of individual subjects. Type 2 cannot be identified with current techniques when performing the pre-analytical phase. Therefore, in addition to a more careful evaluation and validation of the method to be used in clinical practice, the awareness of laboratory professionals should be raised as to the importance of evaluating the quality of biological samples before analysis and to adopt algorithms and approaches in the attempt to reduce problems related to erroneous results due to specific or non-specific interferences.
Subject
Biochemistry (medical),Clinical Biochemistry,General Medicine
Cited by
15 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献