A comprehensive review of upper reference limits reported for (high-)sensitivity cardiac troponin assays: the challenges that lie ahead

Author:

Cardinaels Eline P.M.,Mingels Alma M.A.,Jacobs Leo H.J.,Meex Steven J.R.,Bekers Otto,van Dieijen-Visser Marja P.

Abstract

AbstractCardiac troponins (cTn) are the preferred markers for the diagnosis of acute myocardial infarction (AMI). The guidelines recommend the use of the 99th percentile upper reference concentration of a healthy population as the diagnostic cut-off for AMI. However, a broad range of upper reference limits is still employed, complicating the diagnosis of AMI. This overview is meant to assist laboratory specialists to define an appropriate cut-off value for the diagnosis of AMI. Therefore, we provide an overview of the analytical performance and upper reference limits of seven (high-)sensitivity cTn assays: Roche high-sensitivity cTnT and ADVIA Centaur, Stratus CS, Dimension Vista, Vitros ECi, Access and Architect cTnI assays. It is shown that none of the reference populations completely met the guidelines, including those in package inserts. Forty percent of the studies collected less than the advised minimum of 300 subjects. Many studies (50%) did not report their inclusion criteria, while lower 99th percentile limits were observed when more stringent selection criteria were applied. Higher troponin cut-offs were found in men and elderly subjects, suggesting sex- and age-specific cut-offs would be considered. Therefore, there is still need for a large, rigorously screened reference population to more accurately establish cTn upper reference limits.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Reference61 articles.

1. Rapid measurement of cardiac markers on Stratus CS;Altinier;Clin Chem,2000

2. Clinical effi cacy of two cardiac troponin I assays;Dupuy;Clin Chem Lab Med,2009

3. Assay imprecision and th - percentile reference value of a high - sensitivity cardiac troponin I assay;Collinson;Clin Chem,2009

4. High - sensitivity troponin T as a marker of myocardial injury after radiofrequency catheter ablation;Vasatova;Ann Clin Biochem,2011

5. Performance evaluation and subsequent clinical experience with the Abbott Automated Architect STAT Troponin - I assay;Lam;Clin Chem,2006

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3