Quantification of human complement C2 protein using an automated turbidimetric immunoassay

Author:

Tange Clare Elizabeth1,Johnson-Brett Bridget2,Cook Alex2,Stordeur Patrick3,Brohet Fabian3,Jolles Stephen4,Steven Rachel4,Ponsford Mark4,Roberts Andrew4,El-Shanawany Tariq4,Harding Stephen2,Wallis Gregg2,Parker Antony Richard2

Affiliation:

1. The Binding Site Group Limited , 8 Calthorpe Road , B15 1QT, Birmingham , UK

2. The Binding Site Group Limited , Birmingham , UK

3. Immunobiology Clinic, Erasme Hospital , Université Libre de Bruxelles , Brussels , Belgium

4. Immunodeficiency Centre for Wales , University Hospital of Wales , Cardiff , UK

Abstract

Abstract Background: The measurement of complement components is clinically useful where a deficiency is suspected, or where excessive activation and consumption are present in disease. C2 deficiency carries an increased risk of developing systemic lupus erythematosus, recurrent infections and atherosclerosis. In this study, we have evaluated The Binding Site’s Human Complement C2 SPAPLUS® assay. Methods: Linearity was tested using 13 sample dilutions covering the standard measuring range. Within- and between-assay variabilities were calculated using five samples with different C2 concentrations. The correlation between C2 concentrations in EDTA-plasma and serum was assessed, as was the correlation between C2 measurements by the automated assay and radial immunodiffusion. C2 concentrations were compared with CH50 activity, and quantified in individuals with homozygous or heterozygous C2 deficiency, acquired angioedema and patients with chronic inflammatory conditions. Results: The assay was linear across the measuring range (3.8–42.3 mg/L). Intra- and interassay variability were 2.3%–3.8% and 0%–3.3%, respectively. Comparison between C2 measurements in EDTA-plasma and serum provided a strong correlation (p<0.0001, R2=0.82, slope 0.92), as did the correlation between the automated and radial immunodiffusion methods (p<0.0001, R2=0.89, slope 1.07). A positive correlation between C2 concentration and CH50 activity was demonstrated (p<0.0001, R2=0.48). Significant differences were observed between the median C2 concentrations obtained in healthy controls and the patient clinical samples, with homozygous C2-deficient patients giving below detectable results. Conclusions: This C2 SPAPLUS® assay allows the automated, rapid and precice quantification of complement C2 protein and could therefore be considered as a replacement for older, more time-consuming methods.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry, medical,Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3