Harmonization in hemolysis detection and prevention. A working group of the Catalonian Health Institute (ICS) experience

Author:

Fernandez Pilar,Llopis María Antonia,Perich Carmen,Alsina Maria Jesús,Alvarez Virtudes,Biosca Carmen,Busquets Gloria,Domenech Maria Vicenta,Gómez Rubén,Llovet Isabel,Minchinela Joana,Pastor Rosa,Ruiz Rosa,Tarrés Ester,Ibarz Mercè,Simón Margarita,Montesinos Mercè

Abstract

AbstractHemolysis is the main cause of non-quality samples in clinical laboratories, producing the highest percentage of rejections in the external assurance programs of preanalytical quality. The objective was to: 1) study the agreement between the detection methods and quantification of hemolysis; 2) establish comparable hemolysis interference limits for a series of tests and analytical methods; and 3) study the preanalytical variables which most influence hemolysis production.Different hemoglobin concentration standards were prepared using the reference method. Agreement was studied between automated methods [hemolytic indexes (HI)] and reference method, as well as the interference according to hemolysis degree in various biochemical tests was measured. Preanalytical variables which could influence hemolysis production were studied: type of extraction, type of tubes, transport time, temperature and centrifugation conditions.Good agreement was obtained between hemoglobin concentrations measured using the reference method and HI, for the most of studied analyzers, particularly those giving quantitative HI. The hemolysis interference cut-off points obtained for the majority of tests studied (except LDH, K) are dependent on the method/analyzer utilized. Furthermore, discrepancies have been observed between interference limits recommended by the manufacturer. The preanalytical variables which produce a lower percentage of hemolysis rejections were: centrifugation at the extraction site, the use of lower volume tubes and a transport time under 15 min at room temperature.The setting of interference limits (cut-off) for each used test/method, and the study of preanalytical variability will assist to the results harmonization for this quality indicator.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry, medical,Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3