Analytical evaluation of the performances of Diazyme and BRAHMS procalcitonin applied to Roche Cobas in comparison with BRAHMS PCT-sensitive Kryptor

Author:

Ceriotti Ferruccio1,Marino Irene2,Motta Andrea2,Carobene Anna2

Affiliation:

1. Clinical Laboratory Service, San Raffaele Hospital , Via Olgettina 60 , 20132 Milan , Italy , Phone: +39 0226432282, Fax: +390226432640

2. Clinical Laboratory Service, San Raffaele Hospital , Milan , Italy

Abstract

Abstract Background: Procalcitonin (PCT) is a recognized marker of sepsis, and its use is expanding to antibiotic stewardship. The aim of this study was the evaluation of two methods: Diazyme PCT on Roche Cobas c702 (PCT-D) and BRAHMS PCT on Roche Cobas e602 analyzers (PCT-BR) in comparison with BRAHMS PCT-sensitive Kryptor (PCT-BK). Methods: Imprecision was assessed at six critical concentrations following the CLSI EP5-A3; limits of detection (LoDs) were checked according to CLSI EP17-A2; linearity was tested, and method comparison was performed on 239 serum samples. Results: Overall CVs ranged from 12.58% to 5.97% for PCT-D, from 3.94% to 1.70% for PCT-BR and from 6.57% to 1.90% for PCT-BK. LoDs were 0.143 μg/L, 0.014 μg/L, 0.040 μg/L for PCT-D, PCT-BR and PCT-BK, respectively. The functional assay sensitivity was 0.24 μg/L for PCT-D, 0.045 μg/L for PCT-BK and <0.035 μg/L for PCT-BR. PCT-BR was linear up to 68.7 μg/L, PCT-BK up to 43 μg/L and PCT-D up to 27.2 μg/L. Method comparison: PCT-D=0.6543 PCT-BK+0.014, r=0.8463 (but 0.44 if calculated on 0–5 μg/L range); PCT-BR=0.9125 PCT-BK+0.021, r=0.9917. Cohen’s κ ranged from 45.2% at 0.25 μg/L to 57.0% at 2.00 μg/L between PCT-D and PCT-BK, whereas it ranged from 89% to 81.3% between PCT-BR and PCT-BK. Conclusions: The PCT-D performances were significantly different from those of PCT-BR and PCT-BK regarding sensitivity, precision, linearity and agreement at clinical cutoffs. For some patients with serial testing, significantly deviating results were obtained compared to reference. In contrast to Roche PCT assay, it does not seem feasible to use BRAHMS PCT cutoffs for the Diazyme test.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry, medical,Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3