Commutable whole blood reference materials for hemoglobin A1c validated on multiple clinical analyzers

Author:

Liu Hong,Wong Lingkai,Yong Sharon,Liu QindeORCID,Teo Tang Lin,Lee Tong Kooi,Loh Tze Ping,Sethi Sunil Kumar,Wong Moh Sim,Cosio Shelia Marie Delos Santos,Ho Clement K.M.,Setoh Johnson Weng Sung,Lim Sok Fong Maria,Lee Grace Lay Lay,Khalid Hafash,Lim Sharine,Lam Choong-Weng,Lee Mee-Yin,Yeo Chin Pin,Chincholkar Pallavi Ravikiran,Hawkins Robert,Ng Bih-Yann

Abstract

Abstract Background The measurement of hemoglobin A1c (HbA1c) is important for diagnosing diabetes mellitus as well as assessing glycemic control in diabetic patients. Commutable whole blood certified reference materials (CRMs) are needed in the measurement of HbA1c for method validation and/or as quality controls. Methods We developed three levels of hemolyzed whole blood CRMs for HbA1c. The certified values were determined using liquid chromatography-isotope dilution tandem mass spectrometry method (LC-IDMS/MS) where two “signature” hexapeptides of HbA1c and hemoglobin A0 (HbA0) were used as the calibration standards. The concentrations of the hexapeptide solutions were determined by amino acid analysis by the LC-IDMS/MS method using amino acid CRMs as the calibration standards. The commutability study was conducted by measuring 25 patient specimens and the whole blood CRMs by both LC-IDMS/MS method and various routine methods using six different clinical analyzers. Results The certified values were determined to be 35.1±2.0, 50.3±1.9 and 65.8±2.6 mmol/mol, respectively. These CRMs showed good commutability on five of the six clinical analyzers but showed poor commutability on one of the clinical analyzers that used similar method as two other analyzers where good commutability was observed. Conclusions With certified target values based on metrological traceability and good commutability on most of the clinical analyzers, the developed whole blood CRMs can be used for method validation or as quality control materials in the measurement of HbA1c. The commutability study results also underscored the need of commutability testing of clinical CRMs using various clinical analyzers.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3