Accuracy of determination of the glomerular filtration marker iohexol by European laboratories as monitored by external quality assessment

Author:

Nordin Gunnar1,Ekvall Sara1,Kristoffersson Carolina1,Jonsson Ann-Sofie2,Bäck Sten-Erik3,Rollborn Niclas4,Larsson Anders5

Affiliation:

1. Equalis , Uppsala , Sweden

2. Department of Clinical Chemistry , Landstinget i Värmland , Karlstad , Sweden

3. Department of Clinical Chemistry , Lund University Hospital , Lund , Sweden

4. Department of Medical Sciences, Section of Clinical Chemistry , Uppsala University , Uppsala , Sweden

5. Department of Medical Sciences, Section of Clinical Chemistry , Uppsala University, Akademiska Sjukhuset , Entrance 61, 3rd Floor , Uppsala SE-75185 , Sweden , Phone: +46 18 611 00 00, Fax: +46 18 611 37 03

Abstract

Abstract Background Glomerular filtration is the most important kidney function. The most accurate glomerular filtration rate (GFR) estimates are based on the clearance of exogenous filtration markers. Of these, iohexol is the only exogenous marker that is included in an external quality assessment (EQA) scheme. The aim of the present study was to evaluate the performance of the European laboratories participating in Equalis’ EQA scheme for iohexol. Methods Weighed amounts of iohexol (Omnipaque) were added to plasma samples and distributed to laboratories participating in the EQA scheme for iohexol. All laboratories performed the assays in a blinded fashion. Results The number of participating laboratories varied between 27 and 34 during the study period. Iohexol was determined by HPLC in 77% of the laboratories and by UPLC/MS/MS methods in 15% of the laboratories. The mean interlaboratory coefficient of variation was 4.7% for the HPLC methods and 6.4% for the UPLC/MS/MS methods. The mean bias between calculated and measured iohexol values was –1.3 mg/L (95% confidence interval ±0.3) during the first part of the study period and 0.1 mg/L (±0.3) during the later part. Conclusions The low interlaboratory variation demonstrates that iohexol can be measured reliably by many laboratories and supports the use of iohexol as a GFR marker when there is a need for high quality GFR measurements.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry (medical),Clinical Biochemistry,General Medicine

Reference15 articles.

1. Filler G, Yasin A, Medeiros M. Methods of assessing renal function. Pediatr Nephrol 2014;29:183–92.

2. Soveri I, Berg UB, Bjork J, Elinder CG, Grubb A, Mejare I, et al. Measuring GFR: a systematic review. Am J Kidney Dis 2014;64:411–24.

3. Frennby B, Sterner G. Contrast media as markers of GFR. Eur Radiol 2002;12:475–84.

4. Delanaye P, Melsom T, Ebert N, Back SE, Mariat C, Cavalier E, et al. Iohexol plasma clearance for measuring glomerular filtration rate in clinical practice and research: a review. Part 2: why to measure glomerular filtration rate with iohexol? Clin Kidney J 2016;9:700–4.

5. Delanaye P, Ebert N, Melsom T, Gaspari F, Mariat C, Cavalier E, et al. Iohexol plasma clearance for measuring glomerular filtration rate in clinical practice and research: a review. Part 1: how to measure glomerular filtration rate with iohexol? Clin Kidney J 2016;9:682–99.