Interlaboratory variability of urinary iodine measurements

Author:

Ittermann Till1,Johner Simone2,Below Harald3,Leiterer Matthias4,Thamm Michael5,Remer Thomas2,Völzke Henry1

Affiliation:

1. Institute for Community Medicine , University Medicine Greifswald , Greifswald , Germany

2. DONALD Study Dortmund, Department of Nutritional Epidemiology , Institute of Nutrition and Food Science (IEL) , University of Bonn , Dortmund , Germany

3. Institute of Hygiene and Environmental Medicine , University Medicine Greifswald , Greifswald , Germany

4. Thuringian Regional Institute for Agriculture , Jena , Germany

5. Department of Epidemiology and Health Monitoring , Robert Koch Institute , Berlin , Germany

Abstract

Abstract Background: The iodine status of populations is usually assessed by median urinary iodine concentrations (UIC) in population-based studies, but it is unclear to which extent UIC are comparable across different laboratories. The aim of our study was to investigate the variability of UIC measurements across three well-established German laboratories with long-term clinical-chemical expertise in iodine measurements and to compare these results to the gold standard inductively coupled plasma mass spectrometry (ICP-MS). Methods: UIC levels were measured from 303 urine samples derived from the “Dortmund Nutritional and Anthropometric Longitudinally Designed Study” and from volunteers of the University Medicine Greifswald at four different German laboratories. Three of these laboratories used Sandell-Kolthoff reaction with different digestion methods for UIC measurement (Lab1–Lab3), whereas one laboratory used ICP-MS as gold standard. Results: Median UIC levels were significantly different across the four laboratories (ICP-MS: 77 μg/L; Lab1: 69 μg/L; Lab2: 73 μg/L; Lab3: 111 μg/L). Linear regressions associating UIC levels of Lab1–Lab3 with UIC levels of ICP-MS showed intercepts significantly different from 0 and slopes significantly different from 1. Intraclass correlations (ICC) in comparison to ICP-MS were 0.91 for Lab1, 0.98 for Lab2, and 0.69 for Lab3. Using the digestion method of Lab2 in Lab3 improved the comparison of UIC levels of Lab3 with those from the ICP-MS (ICC=0.89). Conclusions: We have demonstrated larger interlaboratory variations across high-quality laboratories with long-lasting experience in iodine measurements indicating a relevant non-comparability of UIC measurements in iodine monitoring studies. Therefore, standardization of UIC measurements has to be expedited.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry, medical,Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3