Trueness assessment of HbA1c routine assays: are processed EQA materials up to the job?

Author:

Delatour Vincent1,Clouet-Foraison Noémie12,Jaisson Stéphane2,Kaiser Patricia3,Gillery Philippe2

Affiliation:

1. Laboratoire National de Métrologie et d’Essais (LNE) , Paris , France

2. University Hospital of Reims, Laboratory of Biochemistry , Reims , France

3. Instand e.V., Reference Laboratory , Düsseldorf , Germany

Abstract

Abstract Background With the worldwide increase of diabetes mellitus prevalence, ensuring that HbA1c assays are accurate is essential. External quality assessment (EQA) programs enable laboratories to verify that analytical methods perform according to the manufacturers’ specifications. However, assessing trueness requires commutable materials, a property that is rarely characterized for EQA materials. Methods The difference in bias approach was used to assess commutability of 26 processed quality control materials for 17 of the most frequently used HbA1c assays. Involved assays included immuno-assays, enzymatic assays, affinity, ion-exchange HPLC boronate affinity HPLC and capillary electrophoresis. The measurements were performed at manufacturers or expert laboratories. Assay trueness was additionally assessed against the IFCC reference measurement procedure using fresh clinical specimens that were distributed to 450 medical laboratories. Results Commutability of processed EQA materials was highly heterogeneous and globally insufficient to rigorously assess the trueness of HbA1c assays. Using fresh clinical specimens, mean bias was −0.13 mmol/mol for low HbA1c (34 mmol/mol), between +1.0 and +1.3 mmol/mol for intermediate HbA1c (49 and 58 mmol/mol) and +1.2 mmol/mol for elevated HbA1c (90 mmol/mol). Conclusions This study demonstrates that due to insufficient commutability, most processed EQA materials are unsuitable to assess trueness of HbA1c assays and agreement between the different assays. These materials can only provide information on comparability of individual laboratory results with its peers and on assay precision. Using fresh whole blood samples, this study additionally shows that most HbA1c assays are fairly accurate and meet the total allowable error quality target of 5 mmol/mol.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry, medical,Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3