Rule-out of non-ST elevation myocardial infarction by five point of care cardiac troponin assays according to the 0 h/3 h algorithm of the European Society of Cardiology

Author:

Suh Durie1,Keller Dagmar I.2,Hof Danielle3,von Eckardstein Arnold1,Gawinecka Joanna1

Affiliation:

1. Institute for Clinical Chemistry , University Hospital Zurich, University of Zurich , Zurich , Switzerland

2. Emergency Department , University Hospital Zurich , Zurich , Switzerland

3. Unilabs , Dübendorf , Switzerland

Abstract

Abstract Background: Point of care (POC) assays for cardiac troponins I or T (cTnI or cTnT) may accelerate the diagnosis of patients with suspected acute coronary syndrome (ACS). However, their clinical utility according to the 0 h/3 h algorithm recommended by the European Society of Cardiology (ESC) for non-ST elevation myocardial infarction (NSTEMI) is unknown. Methods: Blood samples from 90 patients with suspected ACS were obtained at hospital admission and 3 h later. Concentrations of cTn were determined using five POC assays (AQT90 FLEX cTnI and cTnT; PATHFAST™ cTnI; Stratus CS 200 cTnI; and Triage MeterPro cTnI) and two guideline-acceptable high-sensitivity (hs) immunoassays. Results: For the diagnosis of NSTEMI (n=15), AUCs for Abbott hs-cTnI and Roche hs-cTnT were 0.86 [95% confidence interval (CI), 0.75–0.96] and 0.88 (95% CI, 0.80–0.95), respectively, at admission, and 0.96 and 0.94, respectively, 3 h later. With the 99th percentile cutoff, their sensitivities were 62% and 92%, respectively, at admission, and 77% and 100%, respectively, 3 h later. The PATHFAST™ cTnI assay showed AUCs of 0.90 (95% CI, 0.82–0.97) and 0.94 (95% CI, 0.89–1.00), respectively, and sensitivities of 67% and 75% at admission and 3 h later, respectively. The other cTn POC assays had AUCs of 0.71 (95% CI, 0.53–0.89) to 0.84 (95% CI, 0.71–0.96) and 0.86 (95% CI, 0.72–0.99) to 0.87 (95% CI, 0.75–0.99) and sensitivities of 39%–50% and 62%–77% at admission and 3 h later, respectively. Conclusions: PATHFAST™ cTnI assay proved itself as comparable to ESC-guideline acceptable hs-cTn assays. The lower sensitivity of the other POC assays limits their clinical utility and would require longer follow-up monitoring of patients for the safe NSTEMI rule-out.

Publisher

Walter de Gruyter GmbH

Subject

Biochemistry, medical,Clinical Biochemistry,General Medicine

Cited by 15 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3