Co3O4 nanoparticles embedded in electrospun carbon nanofibers as free-standing nanocomposite electrodes as highly sensitive enzyme-free glucose biosensors

Author:

Mohammadpour-Haratbar Ali1,Mosallanejad Behrooz2,Zare Yasser3,Rhee Kyong Yop4,Park Soo-Jin5

Affiliation:

1. Department of Polymer Engineering & Color Technology, Amirkabir University of Technology , Tehran , Iran

2. Department of Chemistry, Amirkabir University of Technology , Tehran , Iran

3. Biomaterials and Tissue Engineering Research Group, Department of Interdisciplinary Technologies, Breast Cancer Research Center, Motamed Cancer Institute, ACECR , Tehran , Iran

4. Department of Mechanical Engineering (BK21 four), College of Engineering, Kyung Hee University , Yongin , Republic of Korea

5. Department of Chemistry, Inha University , Incheon 22212 , Republic of Korea

Abstract

Abstract Numerous researches have been directed toward enzyme-free biosensors to alleviate the shortcomings encountered with enzymatic biosensors, in particular the intricate enzyme immobilization procedure. Herein, Co3O4/electrospun carbon nanofiber (ECNF) nanocomposites are successfully prepared to be employed as enzyme-free biosensors for diagnosis of glucose. Two parameters including the carbonization time and the amount of Cobalt(ii) acetate tetrahydrate precursor are optimized, which are 5 h and 0.5 g, respectively. The 0.5 Co3O4/ECNF-5 h nanocomposite delivers superior sensitivity (475.72 μA·mM−1·cm−2), broad linear range (2–10 mM), and detection limit (LOD) less than 1 mM (0.82 Mm). In addition, the electrode shows excellent selectivity. The chronoamperometric analysis of 0.5 Co3O4/ECNF-5 h nanocomposite is performed by adding successively glucose analyte and interfering agents to the 0.1 M sodium hydroxide solution. No significant amperometric signal to the interfering agents including uric acid, ascorbic acid, and dopamine is delivered by this electrode, testifying the great selectivity of the electrode toward the diagnosis of target analyte (glucose) in spite of the existence of interfering species. Taking the aforementioned explanations into account, it can be concluded that the Co3O4/ECNF nanocomposite can be an appropriate free-stand electrode for high-performance enzyme-free glucose biosensor.

Publisher

Walter de Gruyter GmbH

Subject

Condensed Matter Physics,General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3