Ultrasonic resonance evaluation method for deep interfacial debonding defects of multilayer adhesive bonded materials

Author:

Guo Canzhi1,Xu Chunguang23,Xiao Dingguo23,Cheng Guanggui1,Zhong Yan1,Ding Jianning14

Affiliation:

1. School of Mechanical Engineering, Jiangsu University , Zhenjiang , 212013 , China

2. School of Mechanical Engineering, Beijing Institute of Technology , Beijing , 100081 , China

3. Key Laboratory of Fundamental Science for Advanced Machining, Beijing Institute of Technology , Beijing , 100081 , China

4. School of Mechanical Engineering, Yangzhou University , Yangzhou , 225009 , China

Abstract

Abstract Multilayer adhesive bonded structures/materials (MABS) are widely used as structural components, especially in the field of aerospace. However, for MABS workpieces, the facts that the weak echo of the deep interfacial debonding defects (DB) caused by the large acoustic attenuation coefficient of each layer and this echo, which generally aliases with the excitation wave and the backwall echo of the surface layer, pose a great challenge for the conventional longitudinal wave ultrasonic nondestructive testing methods. In this work, an ultrasonic resonance evaluation method for deep interfacial DBs of MABS is proposed based on the ultrasonic resonance theory and the aliasing effect of ultrasonic waves in MABS. Theoretical and simulation analysis show that the optimal inspection frequency for II-interfacial DBs is 500 kHz when the shell thickness is 1.5 mm and the ethylene propylene diene monomer (EPDM) thickness is 1.5 mm, and the optimal inspection frequency is 250 kHz when the shell thickness is 1.5 or 2.0 mm and the EPDM thickness is 2.0 mm. Verification experiments show that the presence of a DB in the II-interface causes a resonance effect, and in the same inspection configuration, the larger the defect size, the more pronounced this effect is. This resonance effect manifests itself as an increase in the amplitude and an increase in the vibration time of the A-scan signal as well as a pronounced change in the frequency of the received ultrasonic wave. In addition, the increase in the excitation voltage further highlights the ultrasonic resonance effect. Four imaging methods – the integrations of the signal and the signal envelope curve, the maximum amplitude of the fast Fourier transform (FFT) of the signal, and the signal energy – were used for C-scan imaging of ultrasonic resonance evaluation of MABS’s deep interfacial DBs and all these methods can clearly show the sizes and locations of the artificial defects and internal natural defect. The normalized C-scan imaging method proposed in this study can further highlight the weak changes in the signals in the C-scan image. The research results of this study have laid a solid theoretical and practical foundation for the ultrasonic resonance evaluation of MABS.

Publisher

Walter de Gruyter GmbH

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3