An inter-comparison of isotopic composition of neon via chemical assays and thermal analyses (IUPAC Technical Report)

Author:

Steur Peter P. M.1,Yang Inseok2,Kim Jin Seog2,Nakano Tohru3,Nagao Keisuke4,Pavese Franco5

Affiliation:

1. Istituto Nazionale di Ricerca Metrologica (INRIM) , Torino , Italy

2. Korea Research Institute of Standards and Science (KRISS) , Daejeon , Republic of Korea

3. National Metrology Institute of Japan (NMIJ), AIST , Tsukuba , Japan

4. Division of Polar Earth-System Sciences , KOPRI (Korea Polar Research Institute) , Incheon , Korea

5. Formerly INRIM and Instytut Niskich Temperatur i Badan Strukturalnich , Torino , Italy , Affiliated Scientist (2010–2015)

Abstract

Abstract In 2003–2014, a study on the effect of isotopic composition on the triple point temperature of neon was conducted under the framework of a Project involving laboratories from 11 countries. Natural neon from commercial sources of different isotopic composition, high-purity 20Ne and 22Ne isotopes, and certified artificial isotopic mixtures were used. The thermometric studies comprised: a) a total of 131 analytical assays from 3 laboratories on the isotopic composition of samples taken from 31 different bottles of neon with chemical gas purity 99.99 mol % to 99.9995+ mol %, including chemical impurities for some samples, with up to 12 assays per sample; b) multi-laboratory thermal analyses, with accuracies ranging up to better than 50 μK (k≈2), on 39 samples, almost all permanently sealed in metal cells, for the determination of the liquidus-point temperature of the triple point as a function of isotopic composition. The thermometric studies also constitute an international inter-comparison of thermal and analytical assays on the isotopic composition—and occasionally of the chemical impurities—of neon. These tests are critically needed for top-accuracy thermometry. The main results of the inter-comparison of the various chemical assays, and of the comparisons between the assays and the results of thermal analyses, are reported. They show discrepancies in x(20,21,22Ne), especially for x(22Ne), in ‘natural’ neon, for the same gas bottle, equivalent to an uncertainty of up to 165 μK (k = 1) in the triple point temperature, as measured by all testing laboratories, and of about 100 μK (k = 1) as measured from a single testing laboratory. This is an unsatisfactory situation for thermometry, since it is difficult to obtain a reliable and accurate isotopic assay for neon, thus limiting the accuracy of the realisation of the neon triple point temperature as a ITS-90 reference point to well above 50 μK. However, it also discloses a strong limitation in the relevant analytical chemistry.

Publisher

Walter de Gruyter GmbH

Subject

General Chemical Engineering,General Chemistry

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3