Author:
Hochleitner Gernot,Youssef Almoatazbellah,Hrynevich Andrei,Haigh Jodie N.,Jungst Tomasz,Groll Jürgen,Dalton Paul D.
Abstract
AbstractAdditive manufacturing with electrohydrodynamic direct writing is a promising approach for the production of polymeric microscale objects. In this study we investigate the stability of one such process, melt electrospinning writing, to maintain accurate placement of the deposited fibre throughout the entire print. The influence of acceleration voltage and feeding pressure on the deposited poly(ε-caprolactone) fibre homogeneity is described, and how this affects the variable lag of the jet drawn by the collector movement. Three classes of diameter instabilities were observed that led to poor printing quality: (1) temporary pulsing, (2) continuous pulsing, and (3) regular long bead defects. No breakup of the electrified jet was observed for any of the experiments. A simple approach is presented for the melt electrospinning user to evaluate fibre writing integrity, and adjust the processing parameters accordingly to achieve reproducible and constant diameter fibres.
Subject
Biomedical Engineering,Bioengineering
Cited by
106 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献