The utility of continuous glucose monitoring systems in the management of children with persistent hypoglycaemia

Author:

Vijayanand Sathyakala1ORCID,Stevenson Paul G.2,Grant Maree1,Choong Catherine S.13,Davis Elizabeth A.123,Abraham Mary B.123

Affiliation:

1. Department of Endocrinology and Diabetes , Perth Children’s Hospital , Perth , Western Australia , Australia

2. Telethon Kids Institute, University of Western Australia , Perth , Western Australia , Australia

3. The University of Western Australia , Perth , Western Australia , Australia

Abstract

Abstract Objectives Glucose monitoring is vital in children with persistent hypoglycaemia to reduce the risk of adverse neuro-behavioural outcomes; especially in children with hyperinsulinism. The role of continuous glucose monitoring (CGM) systems in monitoring glucose levels in this cohort is limited. The objective of this study was to ascertain the effectiveness of CGM and to evaluate parents’ experience of using CGM for monitoring glucose levels in children with hypoglycaemia. Methods Retrospective analysis of sensor glucose (SG) values from Dexcom G4 CGM with paired finger-prick blood glucose (BG) values was performed to determine the accuracy of CGM. The parent experience of CGM was assessed using a questionnaire administered to families of children with congenital hyperinsulinism currently attending the clinic. Results SG data from 40 children (median age 6 months) with persistent hypoglycaemia (60% Hyperinsulinism) were analysed. The mean difference between 5,650 paired BG and SG values was 0.28 mmol/L. The sensitivity and specificity of CGM to identify severe hypoglycaemia (BG < 3.0 mmol/L) were 54.3% (95% CI: 39.0%, 69.1%) and 97.4% (95% CI: 96.9%, 97.8%) respectively. Parents (n=11) reported less anxiety (n=9), better sleep at night (n=7) and preferred to use CGM for monitoring (n=9). Conclusions Although the high number of false-positive readings precludes the routine use of CGM in the evaluation of hypoglycaemia, it avoids unnecessary BG testing during normoglycaemia. It is an acceptable tool for parents for monitoring their children who are at risk of hypoglycaemia. Newer CGM systems with improved accuracy at lower glucose levels have the potential to further improve monitoring.

Publisher

Walter de Gruyter GmbH

Subject

Endocrinology,Endocrinology, Diabetes and Metabolism,Pediatrics, Perinatology and Child Health

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3