Occupational safety of pressurized intraperitoneal aerosol chemotherapy (PIPAC)

Author:

Willaert Wouter1,Sessink Paul2,Ceelen Wim13

Affiliation:

1. Department of GI Surgery, Ghent University Hospital, route 1275, De Pintelaan 185, 9000, Ghent, Belgium

2. Exposure Control Sweden AB, Bohus-Björkö, Sweden

3. Cancer research institute Ghent (CRIG), Ghent, Belgium

Abstract

AbstractBackgroundPressurized intraperitoneal aerosol chemotherapy (PIPAC) has emerged as a novel method to treat extensive, small volume peritoneal metastases. The clinical use of chemotherapy containing aerosols represents a potential occupational health hazard. We report the results of toxicological analysis during the first two clinical PIPAC procedures performed at Ghent University Hospital.MethodsAfter extensive preparation and in vitro testing, two patients were treated with PIPAC: the first using doxorubicin (2.86 mg in 51.43 mL) and cisplatin (14.28 mg in 164.3 mL), the second using oxaliplatin (182.10 mg in 186.42 mL). A standardized safety checklist was developed and used. Aerosol delivery was combined with electrostatic precipitation (ePIPAC). The following samples were obtained at several time points and locations: environmental air, floor surface wipes, surgeon’s gloves, surgeon’s hand wipes, circuit filters, and fluid from the water seal collection chamber container placed along the closed aerosol waste evacuating line. Platinum concentration was measured in these samples using voltammetry. Sample collection and analysis were performed by an independent external laboratory.ResultsPlatinum was not detected on the four floor locations after both procedures (detection limit 0.02 ng/cm2). Similarly, no platinum was detected in environmental air during both PIPACs at the surgeon’s or anesthesiologist’s position (detection limit 4.0–27 ng/m3). No platinum contamination was detected on the hands, outer pair of gloves, or inner pair of gloves of the surgeon (detection limit 70 and 50 ng respectively). Platinum was not detected on the filters and in the air-seal container liquid.ConclusionsWith adequate preparation and precautions, a clinical PIPAC program can be established without measurable chemotherapy exposure to the operating room environment or healthcare workers.

Publisher

Walter de Gruyter GmbH

Subject

Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3