Microbiological stability tests with simulated broth preparations and integrity testing for sterile standard cytotoxic preparations

Author:

Matheron Agnès1,Guerault Marie-Noelle1,Vazquez Raphael1,Cheron Mireille1,Brossard Denis12,Crauste-Manciet Sylvie34

Affiliation:

1. CHI Poissy Saint Germain-en-Laye, Saint Germain-en-Laye, France

2. Paris Descartes University, Faculty of Pharmacy, Paris, France

3. University of Bordeaux, ARNA Laboratory U1212 INSERM, UMR 5320 CNRS, Bordeaux, France

4. University Hospital of Bordeaux (CHU), Bordeaux, France

Abstract

AbstractObjectivesThe objectives were to assess the microbiological stability and the physical enclosure integrity of the overwrapping for batch production of standard cytotoxic injectable solutions.MethodsBroth culture media were used in place of cytotoxic drugs to assess the worst case in term of microbiological contamination risk. Iterative sterility tests on batches were performed for 60 days using rapid microbiological method. Validation of microbiological growth of culture media was assessed by direct inoculation of <100 CFU/mL of six microbiological strains recommended by European Pharmacopeia. Validation of the ability of growth of microorganisms in 11 cytotoxic solutions and one monoclonal antibody was assessed using eight strains. In addition, the physical integrity of the seal of the overwrapping containing cytotoxic preparations was assessed by dynamometric method and dye penetration test.ResultsNo microbiological contamination was observed on all units of batches for 60 days of investigation. The ability to detect microbiological growth in cytotoxic solutions was validated for the eight challenge microorganisms after 1/10 dilution for cytotoxic investigated, except for 5 Fluorouracil, gemcitabine and cisplatin. In addition, physical integrity testing of the seal of overwrapping pointed out the need of specific validation of heatsealer and operator education.ConclusionsBesides physico-chemical testing, microbiological stability testing combined to physical integrity testing is the additional part of the development method for batch production of sterile drugs in hospital.

Publisher

Walter de Gruyter GmbH

Subject

Pharmacology (medical),Pharmacology,Pharmacy

Reference82 articles.

1. Possible endotoxin contamination in some antitumor agents preparations: study with the limulus amebocyte lysate test;Farm Ed Prat,1977

2. Effects of methotrexate on group A beta hemolytic streptococci and streptococcal infection;Cancer,1972

3. Possible endotoxin contamination in some antitumor agents preparations: study with the limulus amebocyte lysate test;Farm Ed Prat,1977

4. Microbial inhibitory properties and stability of topotecan hydrochloride injection;Am J Health Syst Pharm,1998

5. Long-term maintenance of sterility in single-use syringes;Am J Health-Syst Pharm,2006

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3