Modern gold standard of cardiac output measurement – A simplified bedside measurement of individual oxygen uptake in the cath lab
Author:
Schmücker Georg1, Burgdorf Christof1, Blohm Jan-Henrik1, Bugno Mathias1, Meyer Kathrin1, Remppis Bjoern Andrew1
Affiliation:
1. Klinik für Kardiologie , Herz- und Gefäßzentrum Bad Bevensen , Bad Bevensen , Germany
Abstract
Abstract
Objectives
Cardiac output (CO) measurements employing the direct Fick principle represent the gold standard in right-sided heart catheterization (RHC). The current widespread approach in hemodynamic workup however uses the indirect Fick principle with assumed values for oxygen uptake (VO2) leading to incorrect CO values in up to 25% of patients. We have tested a contemporary breath-by-breath gas analyzer that allows precise real-time measurements of VO2 with appropriate time and effort to serve the direct Fick principle.
Methods
By means of a small and mobile metabolic cart assembled with widely used components of a standard spiroergometer, we performed bedside measurements of individual VO2. In 33 unselected, consecutive patients with various indications for RHC we compared CO values derived from indirect vs. direct Fick calculations.
Results
In 28 of the 33 patients, VO2 measurements were completed with a plausible dataset within a median of 3.2 (interquartile range 2.8–6.2) min. In nine of the 28 patients, CO values based on measured VO2 values differed by more than 20% from CO calculations based on assumed VO2 values with value deviations scattering over a broad range in both directions (maximally +52% to minimally −46%).
Conclusions
The bedside measurement of VO2 for gold standard CO determination is technically feasible within a few min and can thus be easily included in any RHC protocol. As modern therapy for numerus indications demand a precise upfront measurement of hemodynamics, our method might help to correctly identify patients for costly therapies.
Publisher
Walter de Gruyter GmbH
Subject
Drug Discovery,Pharmacology,General Medicine,Physiology
Reference18 articles.
1. Fick, A. Über die Messung des Blutquantums in den Herzventrikeln. In: Sitzungsberichte der physikalisch-medicinischen Gesellschaft zu Würzburg; 1870:XVI–XVII pp. 2. LaFarge, CG, Miettinen, OS. The estimation of oxygen consumption. Cardiovasc Res 1970;4:23–30. 3. Tonelli, AR, Wang, XF, Abbay, A, Zhang, Q, Ramos, J, McCarthy, K. Can we better estimate resting oxygen cosumption by incorporating arterial blood gases and spirometric determinations? Respir Care 2015;60:517–25. 4. Narang, N, Thibodeau, JT, Levine, BD, Gore, MO, Ayers, CR, Lange, RA, et al.. Inaccuracy of estimated resting oxygen uptake in the clinical setting. Circulation 2014;129:203–10. 5. Fanari, Z, Grove, M, Rajamanickam, A, Hammami, S, Walls, C, Kolm, P, et al.. Cardiac output determination using a widely available direct continuos oxygen consumption measuring device: a practical way to get back to the gold standard. Cardiovasc Revascularization Med 2016;17:256–61.