Accurate measurements of 129I concentration by isotope dilution using MC-ICPMS for half-life determination

Author:

Isnard Hélène1,Nonell Anthony1,Marie Mylène1,Chartier Frédéric2

Affiliation:

1. Commissariat à l'Energie Atomique et aux Energies alternatives (CEA), DEN, DPC, SEARS, LANIE, F-91191 Gif Sur Yvette, France

2. Commissariat à l'Energie Atomique et aux Energies alternatives (CEA), DEN, DPC, F-91191 Gif Sur Yvette, France

Abstract

Abstract Determining the 129I concentration, a long-lived radionuclide present in spent nuclear fuel, is a major issue for nuclear waste disposal purpose. 129I also has to be measured in numerous environmental, nuclear and biological samples. To be able to accurately determine the 129I concentration, an analytical method based on the use of a multicollector-inductively coupled plasma mass spectrometer (MC-ICPMS) combined with an isotope dilution technique using an 127I spike, was developed. First, the influence of different media (HNO3, NaOH and TMAH) on natural 127I signal intensity and stability and on memory effects was studied. Then an analytical procedure was developed by taking into account the correction of blanks and interferences. Tellurium was chosen for instrumental mass bias correction, as no certified standards with suitable 127I/129I ratio are available. Finally, the results, reproducibility and uncertainties obtained for the 129I concentration determined by isotope dilution with a 127I spike are presented and discussed. The final expanded relative uncertainty obtained for the iodine-129 concentration was lower than 0.7% (k = 1). This precise 129I determination in association with further activity measurements of this nuclide on the same sample will render it possible to determine a new value of the 129I half-life with a reduced uncertainty (0.76%, k = 1).

Publisher

Walter de Gruyter GmbH

Subject

Physical and Theoretical Chemistry

Reference37 articles.

1. Iodine de - termination in natural and tap water using inductively coupled plasma mass spectrometry;Takaku;Anal Sci,1995

2. Half - life of and the age of the elements;Katcoff;Phys Rev,1951

3. Deter - mination of chlorine , bromine and iodine in plant samples by inductively coupled plasma - mass spectrometry after leaching with tetramethyl ammonium hydroxide under a mild tempera - ture condition;Tagami;Anal Chim Acta,2006

4. Determination of iodine and molyb - denum in milk by quadrupole ICP - MS;Reid;Talanta,2008

5. A high accuracy primary ratio method for the de - termination of iodine in complex matrices by double isotope dilution using MC - ICPMS and spike At Spectrom;Santamaria;Anal

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3