Abstract

Abstract Proximal humeral shaft fractures can be treated with helically deformed bone plates to reduce the risk of iatrogenic nerve lesion. Controversially to this common surgical technique that was first established in 1999, no biomechanical investigation on humeral helical plating is recorded by other reviews, which focus on proximal fractures exclusively. Does an additional scope for shaft fractures reveal findings of helical testing? The present systematic literature review was performed based on guidelines by Kitchenham et al. to systematically search and synthesize literature regarding biomechanical testing of osteosynthetic systems for proximal humeral shaft fractures. Therefore, a systematic approach to search and screen literature was defined beforehand and applied on the findings of the database PubMed®. Synthesized information of the included literature was categorized, summarized and analyzed via descriptive statistics. Out of 192 findings, 22 publications were included for qualitative synthesis. A wide range of different test methods was identified, leading to a suboptimal comparability of specific results between studies. Overall, 54 biomechanical test scenarios were identified and compared. Physiological based boundary conditions (PB-BC) were referenced in 7 publications only. One study of testing straight and helical dynamic compression plates without PB-BCs was identified, showing significant differences under compressional loading. The absence of test standards of specific fields like humeral fractures lead to a high variance in biomechanical testing of osteosynthetic locking plates for proximal humeral shaft fractures. Physiological approaches offer realistic test scenarios but need to be uniformed for enhanced comparability between studies. The impact of helically deformed locking plates under PB-BC was not identified in literature.

Publisher

Walter de Gruyter GmbH

Subject

Biomedical Engineering

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3